Siemens 3RV1011-1KA20-ZX95 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1011-1KA20-ZX95 SIRIUS Motor Protection Circuit B

MPN3RV1011-1KA20-ZX95

Siemens SIRIUS motor protection circuit breaker, 3RV1011-1KA20-ZX95, 12 A continuous, 5.5 kW at 400 V, CLASS 10 trip, spring-loaded terminals, screw and snap-on DIN rail.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV1011-1KA20-ZX95 — Identification
ParameterValue
SeriesSIRIUS
Product designationcircuit breaker
3RV1011-1KA20-ZX95 — Electrical
ParameterValue
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated impulse withstand voltage (Uimp)6 000 V
Number of poles3
Power loss (AC, hot)9.25 W
Power loss, per pole (AC, hot)3.1 W
3RV1011-1KA20-ZX95 — Protection & Tripping
ParameterValue
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)50 kA
Breaking capacity at 500 V (AC)3 kA
Breaking capacity at 690 V (AC)2 kA
Phase-failure detectionYes
Ground-fault detectionNo
3RV1011-1KA20-ZX95 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
3RV1011-1KA20-ZX95 — Connections
ParameterValue
Main-circuit terminal typespring-loaded terminals
Main-circuit connector arrangementfront side
Conductor cross-section, finely stranded with ferrule2x (0.25 ... 1.5 mm²)
3RV1011-1KA20-ZX95 — Mechanical
ParameterValue
Height90 mm
Width45 mm
Depth81 mm
Mounting positionany
3RV1011-1KA20-ZX95 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
3RV1011-1KA20-ZX95 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

The Siemens SIRIUS 3RV1011-1KA20-ZX95 is a motor protection circuit breaker rated for 12 A continuous current and 5.5 kW at 400 V, with a CLASS 10 trip characteristic — meaning it clears overloads fast enough to protect standard induction motors during start-up without nuisance tripping on normal inrush. Breaking capacity sits at 100 kA at 240 V AC and 50 kA at 400 V AC, then drops to 3 kA at 500 V and 2 kA at 690 V — so for most 400 V line-side faults this breaker clears high-energy arcs without upstream coordination issues. The main circuit uses spring-loaded terminals accepting 2x (0.25... 2.5 mm²) solid or 2x (0.25... 1.5 mm²) finely stranded with ferrule.

Width is 45 mm, height 90 mm, depth 81 mm — fits a standard 45 mm module slot. IP20 on the front; no IP rating on the sides or back, so panel enclosure provides the environmental seal. Shock rated at 25g / 11 ms. Mounting position any.

Frequently asked questions

How do I get current pricing and availability for 3RV1011-1KA20-ZX95?

Submit an RFQ through this listing. Pricing and stock are confirmed at quote time through independent distribution channels.

What is 3RV1011-1KA20-ZX95's listed depth?

The depth is 81 mm.

Will 3RV1011-1KA20-ZX95 drop into a panel specified around 3RV1011-1HA10 without rewiring?

Both are SIRIUS 3RV10 frame breakers with the same 45 mm width and DIN-rail mounting, so the mechanical fit is identical. The wiring difference is in the terminal type: the 1KA20-ZX95 uses spring-loaded terminals, while the 1HA10 uses screw terminals. If the panel was wired for screw terminals, you will need to adapt the conductor terminations — the spring clamp accepts 0.25–2.5 mm² solid or 0.25–1.5 mm² ferrule-stranded.

What compliance documentation does this brand provide for 3RV1011-1KA20-ZX95?

Siemens SIRIUS breakers typically carry IEC/EN 60947-2 and 60947-4-1 certifications, plus UL/CSA listings for the North American market. Specific declarations (RoHS, REACH, CE, UKCA) are available in the manufacturer's documentation package for this order code.