Siemens 3RV1021-0AA10-ZX95 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1021-0AA10-ZX95 SIRIUS Motor Protection Circuit B

MPN3RV1021-0AA10-ZX95

Siemens SIRIUS motor protection circuit breaker, 3RV1021-0AA10-ZX95, 0.16 A continuous, CLASS 10 trip, 100 kA breaking capacity at 400 V, screw terminals, IP20 front, DIN rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3RV1021-0AA10-ZX95 — Identification
ParameterValue
SeriesSIRIUS
Product designationcircuit breaker
3RV1021-0AA10-ZX95 — Electrical
ParameterValue
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated impulse withstand voltage (Uimp)6 000 V
Number of poles3
Power loss (AC, hot)5.5 W
Power loss, per pole (AC, hot)1.8 W
3RV1021-0AA10-ZX95 — Protection & Tripping
ParameterValue
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)100 kA
Phase-failure detectionYes
Ground-fault detectionNo
3RV1021-0AA10-ZX95 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
3RV1021-0AA10-ZX95 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementfront side
Conductor cross-section, finely stranded with ferrule2x (1 ... 2.5 mm²), 2x (2.5 ... 6 mm²)
3RV1021-0AA10-ZX95 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth96 mm
Mounting positionany
3RV1021-0AA10-ZX95 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
3RV1021-0AA10-ZX95 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

Motor protection circuit breaker, 0.16 A, CLASS 10

The Siemens SIRIUS 3RV1021-0AA10-ZX95 is a motor protection circuit breaker rated at 0.16 A continuous current with a CLASS 10 trip characteristic — meaning it will trip within 10 seconds at 7.2x overload, fast enough to protect standard induction motors from locked-rotor heating while allowing normal start-up inrush.

DIN rail mount, IP20 front, 45 mm wide

The 45 mm width and 97 mm height fit a standard 4-module slot in a distribution board; 96 mm depth leaves clearance behind a 120 mm deep enclosure door.

Screw-type terminals on the main circuit accept 2x solid or stranded conductors from 1 to 2.5 mm², or 2x from 2.5 to 6 mm² — fine for the 0.16 A rating, but the terminal range also covers larger wire for the 100 kA fault path. AWG equivalents are 2x 14–10. No auxiliary contacts built in (0 for auxiliary contacts), but the unit accepts an add-on auxiliary switch block if needed.

Operating conditions and environment

Shock resistance is 25g for 11 ms — survives most industrial vibration and transport handling. Mounting position is any orientation.

Frequently asked questions

Where can I buy 3RV1021-0AA10-ZX95 and get a price?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm number.

What is the breaking capacity of 3RV1021-0AA10-ZX95?

100 kA at 240 V, 400 V, 500 V, and 690 V AC — the full rated voltage range, so no derating curve to worry about for most industrial panel feeds.

Will 3RV1021-0AA10-ZX95 drop into a panel specified for 3RV1011-0GA10?

The 3RV1021 frame is wider (45 mm vs 45 mm for the 3RV1011 — same width) and shares the same DIN rail clip, but the 3RV1021 series has a different internal construction and higher breaking capacity. Physically it fits the same slot, but verify the terminal layout and any auxiliary contact arrangement before swapping, as the add-on blocks may differ.