Siemens 3RV1021-0AA15-ZW98 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1021-0AA15-ZW98 SIRIUS Motor Protection Circuit B

MPN3RV1021-0AA15-ZW98

Siemens SIRIUS 3RV1021-0AA15-ZW98, motor protection circuit breaker, 0.16 A continuous rated current, Trip Class 10, 100 kA breaking capacity at 400 V AC, screw-type terminals, snap-on DIN rail mounting.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3RV1021-0AA15-ZW98 — Identification
ParameterValue
SeriesSIRIUS
Product designationcircuit breaker
3RV1021-0AA15-ZW98 — Electrical
ParameterValue
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated impulse withstand voltage (Uimp)6 000 V
Number of poles3
Power loss (AC, hot)5.5 W
Power loss, per pole (AC, hot)1.8 W
3RV1021-0AA15-ZW98 — Protection & Tripping
ParameterValue
Overload release setting range0.11 ... 0.16 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)100 kA
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV1021-0AA15-ZW98 — Endurance & Switching
ParameterValue
Auxiliary CO (changeover) contacts0
3RV1021-0AA15-ZW98 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementfront side
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor range, AWG (main contacts)2x (14 ... 10)
3RV1021-0AA15-ZW98 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth96 mm
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
Mounting positionany
3RV1021-0AA15-ZW98 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Max. installation altitude2 000 m
3RV1021-0AA15-ZW98 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

The Siemens 3RV1021-0AA15-ZW98 is a SIRIUS motor protection circuit breaker sized for a 0.16 A continuous rated current, Trip Class 10, with a 100 kA breaking capacity at 400 V AC. It is designed for motor protection duty, with phase failure detection and screw-type terminals for both main and auxiliary circuits.

What the ratings mean for fit

The 0.16 A continuous current rating sets the motor full-load current this breaker protects — size it to the motor nameplate FLA, not the supply. Trip Class 10 means the bimetal trips within 10 seconds at 7.2× rated current, standard for standard-duty induction motors starting unloaded or with low-inertia loads. The 100 kA breaking capacity at 400 V is the fault current it can safely interrupt without welding contacts or rupturing the case; this is the SCCR for the branch circuit, so verify the available fault current at the panel is at or below this value.

Mounting and integration

Snap-on mounting onto a 35 mm DIN rail per DIN EN 50022. The 45 mm width takes one standard module slot. Screw-type terminals on the main circuit accept 2x (0.5…1.5 mm²) solid or 2x (1…2.5 mm²) stranded; auxiliary control circuit terminals are also screw-type. IP20 on the front means finger-safe from the panel face but not protected against dust ingress into the enclosure — mount inside a rated cabinet.

Lifecycle and sourcing

The lifecycle stage is listed as current production. This part is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time. No official successor has been issued for this order code.

Frequently asked questions

How do I get current pricing and availability for 3RV1021-0AA15-ZW98?

This part is sourced and quoted to order against an RFQ. Submit a request for quote (RFQ) through the storefront; availability and current pricing are confirmed at quote time.

What is the continuous current rating of 3RV1021-0AA15-ZW98?

The continuous rated current is 0.16 A. This is the motor full-load current the breaker is calibrated to protect.

What wire sizes does the 3RV1021-0AA15-ZW98 accept on the main terminals?

Screw-type main terminals accept 2x (0.5…1.5 mm²) solid or 2x (1…2.5 mm²) stranded conductors.

What is the breaking capacity of 3RV1021-0AA15-ZW98 at 400 V?

The breaking capacity is 100 kA at 400 V AC. This is the maximum fault current the breaker can safely interrupt at that voltage.

MPN
3RV1021-0AA15-ZW98