Siemens 3RV1021-0BA10-ZX95 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1021-0BA10-ZX95 SIRIUS Motor Protection Circuit B

MPN3RV1021-0BA10-ZX95

Siemens SIRIUS motor protection circuit breaker, 3RV1021-0BA10-ZX95, 0.2 A continuous, Class 10 trip, 100 kA breaking capacity at 400 V, IP20 front, screw terminals.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3RV1021-0BA10-ZX95 — Identification
ParameterValue
SeriesSIRIUS
Product designationcircuit breaker
3RV1021-0BA10-ZX95 — Electrical
ParameterValue
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated impulse withstand voltage (Uimp)6 000 V
Number of poles3
Power loss (AC, hot)5.5 W
Power loss, per pole (AC, hot)1.8 W
3RV1021-0BA10-ZX95 — Protection & Tripping
ParameterValue
Overload release setting range0.14 ... 0.2 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)100 kA
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV1021-0BA10-ZX95 — Endurance & Switching
ParameterValue
Auxiliary CO (changeover) contacts0
3RV1021-0BA10-ZX95 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementfront side
Conductor cross-section, finely stranded with ferrule2x (1 ... 2.5 mm²), 2x (2.5 ... 6 mm²)
Conductor range, AWG (main contacts)2x (14 ... 10)
3RV1021-0BA10-ZX95 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth96 mm
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
Mounting positionany
3RV1021-0BA10-ZX95 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Max. installation altitude2 000 m
3RV1021-0BA10-ZX95 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

The Siemens 3RV1021-0BA10-ZX95 is a SIRIUS motor protection circuit breaker — a three-pole device sized for a 0.06 kW motor at 400 V, with a continuous current rating of 0.2 A and a Class 10 trip characteristic that clears overloads fast enough to protect a motor winding during a stall without nuisance-tripping on a normal start.

Breaking capacity — what 100 kA means

Rated breaking capacity is 100 kA at 240 V, 400 V, 500 V, and 690 V AC — that means it can safely interrupt a fault current up to 100,000 A at any of those voltages without welding contacts or venting plasma into the enclosure. For a 0.2 A motor branch, that level of fault-interrupt capability is overkill on the load side but essential for the line-side short-circuit rating the panel designer needs to pass the SCCR label.

Main and auxiliary/control circuits use screw-type terminals. Each pole accepts two solid or stranded conductors in the range 1 to 2.5 mm², plus a second pair for 2.5 to 6 mm² — handy for daisy-chaining the line feed through the breaker without a separate terminal block. AWG equivalents are 2x (14 to 10) for the main contacts.

Rated for -20 to +60 °C operating ambient, -50 to +80 °C storage/transport. Shock-tested to 25 g for 11 ms — survives the ride in a panel on a forklift or a conveyor line vibration. Phase-failure detection is built in; ground-fault detection is not. An auxiliary switch can be added via the product extension slot.

Frequently asked questions

What conductor sizes does the 3RV1021-0BA10-ZX95 accept?

Screw terminals accept two solid or stranded conductors in the range 1 to 2.5 mm², plus a second pair for 2.5 to 6 mm² per pole.

MPN
3RV1021-0BA10-ZX95