Siemens 3RV1021-0BA15-ZW98 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1021-0BA15-ZW98 SIRIUS Motor Protection Circuit B

MPN3RV1021-0BA15-ZW98

Siemens SIRIUS motor protection circuit breaker, 3RV1021-0BA15-ZW98, 0.2 A continuous rated current, CLASS 10 trip, 100 kA breaking capacity at 400 V AC, screw terminals, IP20 front.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV1021-0BA15-ZW98 — Identification
ParameterValue
SeriesSIRIUS
Product designationcircuit breaker
3RV1021-0BA15-ZW98 — Electrical
ParameterValue
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated impulse withstand voltage (Uimp)6 000 V
Number of poles3
Power loss (AC, hot)5.5 W
Power loss, per pole (AC, hot)1.8 W
3RV1021-0BA15-ZW98 — Protection & Tripping
ParameterValue
Overload release setting range0.14 ... 0.2 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)100 kA
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV1021-0BA15-ZW98 — Endurance & Switching
ParameterValue
Auxiliary CO (changeover) contacts0
3RV1021-0BA15-ZW98 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementfront side
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor range, AWG (main contacts)2x (14 ... 10)
3RV1021-0BA15-ZW98 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth96 mm
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
Mounting positionany
3RV1021-0BA15-ZW98 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Max. installation altitude2 000 m
3RV1021-0BA15-ZW98 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

It is rated for a continuous current of 0.2 A and trips in CLASS 10, meaning it will clear a stalled-rotor overload within 10 seconds at 7.2× rated current — fast enough to protect small motors without nuisance tripping on normal starts. Breaking capacity sits at 100 kA across the board — at 240 V, 400 V, 500 V, and 690 V AC — so it handles high-fault-current panels without cascading upstream. The 690 V rated insulation voltage matches the maximum circuit voltage in many industrial motor branches.

Depth is 96 mm, so check enclosure depth if you're retrofitting into a shallow gland box. Solid wire accepts 2× (0.5…1.5 mm²) and 2× (0.75…2.5 mm²); stranded accepts 2× (1…2.5 mm²) and 2× (2.5…6 mm²). AWG for main contacts is 2× (14…10). The auxiliary switch is transverse design and the product extension supports adding auxiliary switches. IP20 on the front — sealed against fingers but not dust or washdown.

Shock rated at 25g / 11 ms. Substance prohibitance date is 01.05.2012 — RoHS compliance is implied for that EU effective date.

Frequently asked questions

Where can I buy 3RV1021-0BA15-ZW98 and how do I get a price?

This part is sourced to order through independent distribution. Submit an RFQ for current availability and pricing — confirmed at quote time.

What is the breaking capacity of this breaker?

100 kA at 240 V, 400 V, 500 V, and 690 V AC — the same rating across all listed voltages.

What compliance documentation does this brand provide for 3RV1021-0BA15-ZW98?

The substance prohibitance date of 01.05.2012 indicates RoHS compliance per EU Directive 2011/65/EU. Phase failure detection is included; ground fault detection is not.