Skip to main content
Siemens 3RV1021-0CA15-ZW97 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1021-0CA15-ZW97 SIRIUS Motor Protection Breaker,

MPN3RV1021-0CA15-ZW97

Siemens SIRIUS 3RV1021-0CA15-ZW97 motor protection circuit breaker, 0.25 A continuous current, Class 10 trip, 100 kA breaking capacity at 400 V AC, screw terminals, snap-on 35 mm DIN rail.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3RV1021-0CA15-ZW97 — Identification
ParameterValue
SeriesSIRIUS
Product designationcircuit breaker
3RV1021-0CA15-ZW97 — Electrical
ParameterValue
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated impulse withstand voltage (Uimp)6 000 V
Number of poles3
Power loss (AC, hot)5.5 W
Power loss, per pole (AC, hot)1.8 W
3RV1021-0CA15-ZW97 — Protection & Tripping
ParameterValue
Overload release setting range0.18 ... 0.25 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)100 kA
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV1021-0CA15-ZW97 — Endurance & Switching
ParameterValue
Auxiliary CO (changeover) contacts0
3RV1021-0CA15-ZW97 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementfront side
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor range, AWG (main contacts)2x (14 ... 10)
3RV1021-0CA15-ZW97 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth96 mm
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
Mounting positionany
3RV1021-0CA15-ZW97 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Max. installation altitude2 000 m
3RV1021-0CA15-ZW97 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

Depth is 96 mm, width 45 mm, height 97 mm — fits a standard 45 mm-wide module slot. Screw terminals on both main and auxiliary circuits accept solid conductors from 0.5 mm² up to 2.5 mm² (two per clamp) and stranded up to 6 mm². Mounting position is any, so orientation in a crowded enclosure isn't a constraint.

Frequently asked questions

Where can I buy 3RV1021-0CA15-ZW97 and how do I get a price?

We source this part to order against an RFQ — availability and current pricing are confirmed at quote time. Submit an RFQ through our site for a firm price and lead time.

What is the breaking capacity of 3RV1021-0CA15-ZW97?

The breaking capacity is 100 kA at 240 V, 400 V, 500 V, and 690 V AC, so it handles high fault currents across common industrial supply voltages.

Does 3RV1021-0CA15-ZW97 detect phase failure?

Yes, phase failure detection is built in — the breaker will trip if one phase drops out, protecting the motor from single-phasing.

What compliance documentation does Siemens provide for 3RV1021-0CA15-ZW97?

The part complies with RoHS (effective 01.05.2012). For UL, IEC, and REACH documentation, contact us with your RFQ and we can provide the relevant certificates.

MPN
3RV1021-0CA15-ZW97