Siemens 3RV1021-0DA10 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1021-0DA10 SIRIUS Motor Protection Circuit Breake

MPN3RV1021-0DA10

Siemens SIRIUS 3RV1021-0DA10 motor protection circuit breaker, 0.32 A rated current, CLASS 10 trip, 100 kA breaking capacity at 400 V AC, IP20 finger-safe, screw terminals.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3RV1021-0DA10 — Identification
ParameterValue
SeriesSIRIUS
Product designationcircuit breaker
3RV1021-0DA10 — Electrical
ParameterValue
Rated impulse withstand voltage (Uimp)6 000 V
Number of poles3
Power loss (AC, hot)5.5 W
Power loss, per pole (AC, hot)1.8 W
3RV1021-0DA10 — Protection & Tripping
ParameterValue
Overload release setting range0.22 ... 0.32 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)100 kA
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV1021-0DA10 — Endurance & Switching
ParameterValue
Auxiliary CO (changeover) contacts0
3RV1021-0DA10 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementfront side
Conductor cross-section, finely stranded with ferrule2x (1 ... 2.5 mm²), 2x (2.5 ... 6 mm²)
Conductor range, AWG (main contacts)2x (14 ... 10)
3RV1021-0DA10 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth96 mm
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
Mounting positionany
3RV1021-0DA10 — Environmental
ParameterValue
Max. installation altitude2 000 m
3RV1021-0DA10 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

Motor protection circuit breaker for 0.09 kW loads

The Siemens 3RV1021-0DA10 is a SIRIUS motor protection circuit breaker rated for 0.32 A continuous current and 0.09 kW at 400 V. Ground fault detection is not included — that function is handled separately upstream or by a downstream RCD. Breaking capacity is 100 kA across the board at 240 V, 400 V, 500 V, and 690 V AC. That is a high-interrupting rating for a 0.32 A device, giving selectivity headroom in a distribution panel without needing a current-limiting upstream breaker.

Any mounting position is allowed. Screw-type terminals on both main and auxiliary circuits accept solid or stranded conductors: 2× (1 to 2.5 mm²) and 2× (2.5 to 6 mm²) per clamp, or AWG 14 to 10. The IP20 front protection and finger-safe touch protection mean it can be installed in open panels without additional shrouding.

Thermal and environmental limits

This matters for enclosure thermal rise calculations — in a sealed panel with multiple breakers, the cumulative heat can derate adjacent devices. Shock resistance is 25 g for 11 ms, suitable for machine-mounted applications with moderate vibration. Rated impulse withstand voltage is 6 kV, and the maximum operating voltage is 690 V AC. The maximum switching frequency under AC-3 duty is 15 operations per hour — adequate for motor starting cycles but not for high-speed jogging applications.

Frequently asked questions

Will 3RV1021-0DA10 drop into a panel specified for 3RV1011-0GA10?

Both are 45 mm wide SIRIUS breakers on 35 mm DIN rail with screw terminals, so the footprint and mounting are compatible. However, the 3RV1021-0DA10 is rated 0.32 A CLASS 10, while the 3RV1011-0GA10 covers a different current range — verify the motor FLA matches before swapping.