Siemens SIRIUS motor protection circuit breaker, 3RV1021-0DA10-ZW98, 0.32 A continuous current, CLASS 10 trip class, 100 kA breaking capacity at 400 V AC, screw terminals, IP20 front.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV1021-0DA10-ZW98 — Identification
ParameterValue
SeriesSIRIUS
Product designationcircuit breaker
3RV1021-0DA10-ZW98 — Electrical
ParameterValue
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated impulse withstand voltage (Uimp)6 000 V
Number of poles3
Power loss (AC, hot)5.5 W
Power loss, per pole (AC, hot)1.8 W
3RV1021-0DA10-ZW98 — Protection & Tripping
ParameterValue
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)100 kA
Phase-failure detectionYes
Ground-fault detectionNo
3RV1021-0DA10-ZW98 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
3RV1021-0DA10-ZW98 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementfront side
Conductor cross-section, finely stranded with ferrule2x (1 ... 2.5 mm²), 2x (2.5 ... 6 mm²)
3RV1021-0DA10-ZW98 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth96 mm
Mounting positionany
3RV1021-0DA10-ZW98 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
3RV1021-0DA10-ZW98 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

Its breaking capacity is 100 kA at 400 V AC (also 100 kA at 240 V, 500 V, and 690 V AC), so it can safely interrupt a fault current up to that level without upstream fuses or breakers needing to coordinate — a strong SCCR (short-circuit current rating) for a device this compact.

Dimensions are 45 mm wide, 97 mm high, 96 mm deep — a 45 mm footprint that fits a standard 45 mm slot in a motor control center (MCC) bucket or a standalone DIN-rail enclosure.

Main circuit terminals are screw-type, accepting solid or stranded conductors: 2x (1... 2.5 mm²) and 2x (2.5... 6 mm²) per clamp — enough for the 0.32 A rating but also for the larger wire sizes needed to carry the fault current without overheating the terminal. Auxiliary switch option is present, though no auxiliary contacts are pre-installed (0 for auxiliary contacts,) — the buyer adds the aux block separately if remote status is needed.

MPN