Siemens 3RV1021-0DA10-ZW98 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1021-0DA10-ZW98 SIRIUS Motor Protection Circuit B

MPN3RV1021-0DA10-ZW98

Siemens SIRIUS motor protection circuit breaker, 3RV1021-0DA10-ZW98, 0.32 A continuous current, CLASS 10 trip class, 100 kA breaking capacity at 400 V AC, screw terminals, IP20 front.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3RV1021-0DA10-ZW98 — Identification
ParameterValue
SeriesSIRIUS
Product designationcircuit breaker

Electrical

3RV1021-0DA10-ZW98 — Electrical
ParameterValue
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated impulse withstand voltage (Uimp)6 000 V
Number of poles3
Power loss (AC, hot)5.5 W
Power loss, per pole (AC, hot)1.8 W

Protection & Tripping

3RV1021-0DA10-ZW98 — Protection & Tripping
ParameterValue
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)100 kA
Phase-failure detectionYes
Ground-fault detectionNo

Endurance & Switching

3RV1021-0DA10-ZW98 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h

Connections

3RV1021-0DA10-ZW98 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementfront side
Conductor cross-section, finely stranded with ferrule2x (1 ... 2.5 mm²), 2x (2.5 ... 6 mm²)

Mechanical

3RV1021-0DA10-ZW98 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth96 mm
Mounting positionany

Environmental

3RV1021-0DA10-ZW98 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C

Specifications

3RV1021-0DA10-ZW98 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

What this part is and what it does

The Siemens SIRIUS 3RV1021-0DA10-ZW98 is a motor protection circuit breaker designed for motor protection, rated at 0.32 A continuous current with a CLASS 10 trip characteristic — meaning it will trip on overload fast enough to protect a standard induction motor before the winding temperature exceeds its limit, provided the motor's thermal time constant aligns with that curve. Its breaking capacity is 100 kA at 400 V AC (also 100 kA at 240 V, 500 V, and 690 V AC), so it can safely interrupt a fault current up to that level without upstream fuses or breakers needing to coordinate — a strong SCCR (short-circuit current rating) for a device this compact. Phase failure detection is built in, which is critical for three-phase motor protection: if one phase drops out, the breaker will trip before single-phasing cooks the motor.

Mounting and integration

Mounts via screw and snap-on onto a 35 mm standard mounting rail per DIN EN 50022 — the same rail used across the SIRIUS family, so it clips into the same panel profile as the contactor and overload relay downstream. Dimensions are 45 mm wide, 97 mm high, 96 mm deep — a 45 mm footprint that fits a standard 45 mm slot in a motor control center (MCC) bucket or a standalone DIN-rail enclosure. IP20 on the front means finger-safe from the panel face; the rear and sides are open to the enclosure interior, so the enclosure itself must provide the environmental seal.

Wiring and terminals

Main circuit terminals are screw-type, accepting solid or stranded conductors: 2x (1... 2.5 mm²) and 2x (2.5... 6 mm²) per clamp — enough for the 0.32 A rating but also for the larger wire sizes needed to carry the fault current without overheating the terminal. Auxiliary switch option is present, though no auxiliary contacts are pre-installed (0 for auxiliary contacts,) — the buyer adds the aux block separately if remote status is needed.

MPN
3RV1021-0DA10-ZW98