Siemens 3RV1021-0DA15 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1021-0DA15 SIRIUS Motor Protection Circuit Breake

MPN3RV1021-0DA15

Siemens SIRIUS 3RV1021-0DA15 motor protection circuit breaker, 0.32 A continuous current, CLASS 10 trip class, 100 kA breaking capacity at 400 V AC, screw-type terminals, IP20 front protection.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV1021-0DA15 — Identification
ParameterValue
SeriesSIRIUS
Product designationcircuit breaker
3RV1021-0DA15 — Electrical
ParameterValue
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated impulse withstand voltage (Uimp)6 000 V
Number of poles3
Power loss (AC, hot)5.5 W
Power loss, per pole (AC, hot)1.8 W
3RV1021-0DA15 — Protection & Tripping
ParameterValue
Overload release setting range0.22 ... 0.32 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)100 kA
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV1021-0DA15 — Endurance & Switching
ParameterValue
Auxiliary CO (changeover) contacts0
3RV1021-0DA15 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementfront side
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor range, AWG (main contacts)2x (14 ... 10)
3RV1021-0DA15 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth96 mm
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
Mounting positionany
3RV1021-0DA15 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Max. installation altitude2 000 m
3RV1021-0DA15 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

Breaking capacity and fault clearing

Rated breaking capacity hits 100 kA across the full AC range from 240 V to 690 V.

Any mounting position is allowed, and zero clearance is required at the sides or rear — you can pack these tight in a panel without derating for airflow.

Auxiliary contacts and control signals

The auxiliary switch is a transverse design, rated 1 A at 24 V, 0.5 A at 230 V, and 0.15 A at 60 V. These are the contact ratings for the signal side — feeding a PLC input or a contactor coil. The main circuit terminals accept solid conductors from 0.5 to 2.5 mm² and stranded from 1 to 6 mm², using screw-type terminals on both main and auxiliary circuits.

Sourcing note

This is a current-production Siemens SIRIUS part, sourced through independent distribution channels.

Frequently asked questions

Where can I buy 3RV1021-0DA15 and get current pricing?

The 3RV1021-0DA15 is sourced to order through independent distribution. Submit an RFQ for current pricing and availability confirmation at quote time.

What is the breaking capacity of 3RV1021-0DA15 at 400 V?

The breaking capacity is 100 kA at 400 V AC, and the same 100 kA rating holds across 240 V, 500 V, and 690 V AC.

Does 3RV1021-0DA15 detect phase failure?

Yes, phase failure detection is included. Ground fault detection is not provided.

What wire sizes fit the terminals on 3RV1021-0DA15?

Main circuit screw terminals accept solid conductors 2x (0.5 to 1.5 mm²) and 2x (0.75 to 2.5 mm²), and stranded conductors 2x (1 to 2.5 mm²) and 2x (2.5 to 6 mm²).

MPN
3RV1021-0DA15