Skip to main content
Siemens 3RV1021-0DA15-ZW97 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1021-0DA15-ZW97 SIRIUS Motor Protection CB, 0.32

MPN3RV1021-0DA15-ZW97

Siemens SIRIUS motor protection circuit breaker, 3RV1021-0DA15-ZW97, 0.32 A continuous rated current, Class 10 trip, 100 kA breaking capacity at 400 V AC, screw terminals, snap-on 35 mm DIN rail.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV1021-0DA15-ZW97 — Identification
ParameterValue
SeriesSIRIUS
Product designationcircuit breaker
3RV1021-0DA15-ZW97 — Electrical
ParameterValue
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated impulse withstand voltage (Uimp)6 000 V
Number of poles3
Power loss (AC, hot)5.5 W
Power loss, per pole (AC, hot)1.8 W
3RV1021-0DA15-ZW97 — Protection & Tripping
ParameterValue
Overload release setting range0.22 ... 0.32 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)100 kA
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV1021-0DA15-ZW97 — Endurance & Switching
ParameterValue
Auxiliary CO (changeover) contacts0
3RV1021-0DA15-ZW97 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementfront side
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor range, AWG (main contacts)2x (14 ... 10)
3RV1021-0DA15-ZW97 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth96 mm
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
Mounting positionany
3RV1021-0DA15-ZW97 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Max. installation altitude2 000 m
3RV1021-0DA15-ZW97 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

Continuous rated current is 0.32 A with Trip Class CLASS 10.

IP20 protection on the front means it is finger-safe for panel installation but not rated for washdown environments. Wire sizes: solid conductors accept 2x (0.5…1.5 mm²) and 2x (0.75…2.5 mm²); stranded accept 2x (1…2.5 mm²) and 2x (2.5…6 mm²); AWG for main contacts is 2x (14…10).

Shock resistance rated at 25g for 11 ms. Substance prohibitance (RoHS compliance) dated 01.05.2012.

Frequently asked questions

Does 3RV1021-0DA15-ZW97 have phase failure detection?

Yes, it includes phase failure detection; it does not include ground fault detection.

MPN
3RV1021-0DA15-ZW97