Skip to main content
Siemens 3RV1021-0EA10-ZW98 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1021-0EA10-ZW98 SIRIUS Motor Protection Breaker,

MPN3RV1021-0EA10-ZW98

Siemens SIRIUS 3RV1021-0EA10-ZW98, motor protection circuit breaker, 0.4 A continuous, 100 kA breaking capacity at 400 V, Class 10 trip, 3-pole, screw terminals, IP20 front.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV1021-0EA10-ZW98 — Identification
ParameterValue
SeriesSIRIUS
Product designationcircuit breaker
3RV1021-0EA10-ZW98 — Electrical
ParameterValue
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated impulse withstand voltage (Uimp)6 000 V
Number of poles3
Power loss (AC, hot)5.5 W
Power loss, per pole (AC, hot)1.8 W
3RV1021-0EA10-ZW98 — Protection & Tripping
ParameterValue
Overload release setting range0.28 ... 0.4 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)100 kA
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV1021-0EA10-ZW98 — Endurance & Switching
ParameterValue
Auxiliary CO (changeover) contacts0
3RV1021-0EA10-ZW98 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementfront side
Conductor cross-section, finely stranded with ferrule2x (1 ... 2.5 mm²), 2x (2.5 ... 6 mm²)
Conductor range, AWG (main contacts)2x (14 ... 10)
3RV1021-0EA10-ZW98 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth96 mm
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
Mounting positionany
3RV1021-0EA10-ZW98 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Max. installation altitude2 000 m
3RV1021-0EA10-ZW98 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

The Siemens 3RV1021-0EA10-ZW98 is a SIRIUS motor protection circuit breaker designed for 3-pole main current circuits, rated at 0.4 A continuous current with a Class 10 trip characteristic. It provides phase failure detection and delivers 100 kA breaking capacity across 240 V, 400 V, 500 V, and 690 V AC — meaning it can safely interrupt a bolted fault up to that level without cascading upstream, even on a 400 V line. That 100 kA figure is the same at all four voltage points, so the SCCR is flat across the operating range, not derated at higher voltage. Rated power at 400 V is 0.09 kW, which sizes it for small motor loads — fractional-horsepower pumps, fans, or conveyor drives. The 5.5 W power loss in hot operating state (1.8 W per pole) is low enough that panel ventilation requirements are minimal; you can pack it tight in a control cabinet without thermal worry.

Screw-type terminals on both main and auxiliary circuits accept solid or stranded conductors: 2x (1... 2.5 mm²) and 2x (2.5... 6 mm²), or AWG 14 to 10 for the main contacts. Finely stranded with core-end processing (ferruled) uses the same ranges. This gives flexibility for panel wiring with either solid or flexible cable.

Shock resistance is 25g for 11 ms, which is typical for industrial panel-mounted gear — it will hold calibration through shipping vibration and plant floor impacts. Front protection class is IP20, meaning finger-safe but not washdown-rated; keep it inside a cabinet.

Sourcing reality

Frequently asked questions

What is the breaking capacity of this breaker at 400 V?

100 kA at 400 V AC, and the same 100 kA rating holds at 240 V, 500 V, and 690 V AC — the SCCR is flat across the voltage range.

Does this breaker detect phase failure?

Yes, phase failure detection is included. Ground fault detection is not available on this variant.

What wire sizes does the screw terminal accept?

Solid and stranded conductors: 2x (1... 2.5 mm²) and 2x (2.5... 6 mm²). AWG for main contacts is 2x (14... 10). Finely stranded with ferrule uses the same ranges.

Where can I buy 3RV1021-0EA10-ZW98?

Sourced and quoted to order against an RFQ through independent distribution. Submit a request for quote; availability and current pricing are confirmed at quote time.

MPN
3RV1021-0EA10-ZW98