Skip to main content
Siemens 3RV1021-0FA10-ZX95 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1021-0FA10-ZX95 SIRIUS Motor Protection Circuit B

MPN3RV1021-0FA10-ZX95

Siemens SIRIUS motor protection circuit breaker, 3RV1021-0FA10-ZX95, 0.5 A rated continuous current, CLASS 10 trip class, 100 kA breaking capacity at 400 V AC, screw-type terminals, snap-on 35 mm DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV1021-0FA10-ZX95 — Identification
ParameterValue
SeriesSIRIUS
Product designationcircuit breaker
3RV1021-0FA10-ZX95 — Electrical
ParameterValue
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated impulse withstand voltage (Uimp)6 000 V
Number of poles3
Power loss (AC, hot)5.5 W
Power loss, per pole (AC, hot)1.8 W
3RV1021-0FA10-ZX95 — Protection & Tripping
ParameterValue
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)100 kA
Phase-failure detectionYes
Ground-fault detectionNo
3RV1021-0FA10-ZX95 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
3RV1021-0FA10-ZX95 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementfront side
Conductor cross-section, finely stranded with ferrule2x (1 ... 2.5 mm²), 2x (2.5 ... 6 mm²)
3RV1021-0FA10-ZX95 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth96 mm
Mounting positionany
3RV1021-0FA10-ZX95 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
3RV1021-0FA10-ZX95 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

The Siemens SIRIUS 3RV1021-0FA10-ZX95 is a motor protection circuit breaker designed for 0.5 A continuous current in AC-3 duty, with a CLASS 10 trip characteristic that clears overloads before the motor windings exceed thermal limits — every shot the same, no scrap on the floor from nuisance trips or missed faults. Rated breaking capacity holds at 100 kA across the full voltage range: 240 V, 400 V, 500 V, and 690 V AC, so it safely interrupts faults up to that level without cascading upstream — a single breaker covers the panel's SCCR requirement. Mounts via screw or snap-on onto 35 mm standard mounting rail per DIN EN 50022, with zero clearance required at the sides or rear — 45 mm wide, 97 mm tall, 96 mm deep, fitting tight gland-plate layouts without derating.

Motor protection and trip coordination

That's the spec that keeps the line running when a contactor drops a leg. For a 0.5 A motor branch, that's the difference between a coordinated trip and a welded contactor. Mechanical endurance rated at 100,000 operations of the main contacts.

Main circuit terminals are screw-type, accepting 2× (1 … 2.5 mm²) solid or 2× (2.5 … 6 mm²) stranded, with AWG equivalents 2× (14 … 10). Finely stranded conductors with core-end processing use the same ranges. An auxiliary switch is available as an add-on (not included in the base unit), letting the breaker signal its trip state back to a PLC or status lamp without a separate control relay.

Environmental and installation constraints

Operates from -20 °C to +60 °C, stores and transports from -50 °C to +80 °C — fine for unheated warehouses or roof-mounted enclosures in temperate climates. Shock rated at 25 g for 11 ms, so it holds calibration on a press or conveyor with intermittent vibration. Mounting position is any orientation, simplifying panel layout. Front face is IP20 — finger-safe but not washdown-rated; install inside a sealed enclosure if the panel sees coolant mist or washdown spray.

Frequently asked questions

Will 3RV1021-0FA10-ZX95 drop into a panel specified around 3RV1011-0GA10 without rewiring?

Both mount on 35 mm DIN rail per DIN EN 50022 and share the same 45 mm width, but the 3RV1021 series has different terminal layouts and trip characteristics — verify the terminal assignments and the 0.5 A continuous rating against your motor FLA before swapping.

MPN