Skip to main content
Siemens 3RV1021-0GA10-ZW98 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1021-0GA10-ZW98 SIRIUS Motor Protection Circuit B

MPN3RV1021-0GA10-ZW98

Siemens SIRIUS 3RV1021-0GA10-ZW98 motor protection circuit breaker, 0.63 A continuous current, CLASS 10 trip class, 100 kA breaking capacity at 400 V AC, screw-type terminals, snap-on DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV1021-0GA10-ZW98 — Identification
ParameterValue
SeriesSIRIUS
Product designationcircuit breaker
3RV1021-0GA10-ZW98 — Electrical
ParameterValue
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated impulse withstand voltage (Uimp)6 000 V
Number of poles3
Power loss (AC, hot)5.5 W
Power loss, per pole (AC, hot)1.8 W
3RV1021-0GA10-ZW98 — Protection & Tripping
ParameterValue
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)100 kA
Phase-failure detectionYes
Ground-fault detectionNo
3RV1021-0GA10-ZW98 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
3RV1021-0GA10-ZW98 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementfront side
Conductor cross-section, finely stranded with ferrule2x (1 ... 2.5 mm²), 2x (2.5 ... 6 mm²)
3RV1021-0GA10-ZW98 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth96 mm
Mounting positionany
3RV1021-0GA10-ZW98 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
3RV1021-0GA10-ZW98 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

Motor protection circuit breaker, 0.63 A, CLASS 10

Breaking capacity is 100 kA across the full AC voltage range from 240 V to 690 V, so it can be applied on high-fault-current panels without requiring an upstream current-limiting fuse for most installations. The unit mounts via screw or snap-on onto a 35 mm DIN rail per EN 50022, occupies 45 mm width, and accepts screw-type terminals for the main circuit — solid or stranded conductors from 1 to 6 mm².

Integration and deployment

Designed for motor protection in control panels, the 3RV1021-0GA10-ZW98 includes phase failure detection and is rated for any mounting position, with an IP20 front face — suitable for enclosed panel installation where personnel contact is limited to the front. Shock resistance is 25 g for 11 ms, and surge voltage withstand is 6 kV. The breaker is rated for a maximum altitude of 2000 m and has a mechanical life of 100,000 operations.

Frequently asked questions

What is 3RV1021-0GA10-ZW98's listed depth?

The listed depth is 96 mm.

What conductor sizes does the 3RV1021-0GA10-ZW98 accept?

The screw-type terminals accept solid or stranded conductors: 2x (1 to 2.5 mm²) and 2x (2.5 to 6 mm²).

MPN
3RV1021-0GA10-ZW98