Skip to main content
Siemens 3RV1021-0GA15-ZW97 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1021-0GA15-ZW97 SIRIUS Motor Protection Circuit B

MPN3RV1021-0GA15-ZW97

Siemens SIRIUS motor protection circuit breaker, 3RV1021-0GA15-ZW97, 0.63 A continuous rating, Class 10 trip class, 100 kA breaking capacity at 400 V AC, screw and snap-on DIN rail mounting.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV1021-0GA15-ZW97 — Identification
ParameterValue
SeriesSIRIUS
Product designationcircuit breaker
3RV1021-0GA15-ZW97 — Electrical
ParameterValue
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated impulse withstand voltage (Uimp)6 000 V
Number of poles3
Power loss (AC, hot)5.5 W
Power loss, per pole (AC, hot)1.8 W
3RV1021-0GA15-ZW97 — Protection & Tripping
ParameterValue
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)100 kA
Phase-failure detectionYes
Ground-fault detectionNo
3RV1021-0GA15-ZW97 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
3RV1021-0GA15-ZW97 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementfront side
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
3RV1021-0GA15-ZW97 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth96 mm
Mounting positionany
3RV1021-0GA15-ZW97 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
3RV1021-0GA15-ZW97 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

It provides overload and short-circuit protection for motors up to 0.18 kW at 400 V, with a continuous current rating of 0.63 A and a Class 10 trip characteristic. This prevents nuisance tripping on startup while still protecting the motor winding. The unit includes phase failure detection, which disconnects the motor if one phase is lost — a common cause of single-phasing damage in three-phase motor loads.

Breaking capacity and short-circuit performance

Rated breaking capacity is 100 kA at 240 V, 400 V, 500 V, and 690 V AC — a flat high-fault curve that covers most industrial distribution panels without needing upstream current-limiting fuses.

Dimensions: 45 mm wide, 97 mm high, 96 mm deep. The 96 mm depth means it will clear most standard 120 mm deep enclosures without a sub-panel extension. Mounting position is any orientation; no derating required for side-by-side or inverted mounting. Front face is IP20 rated — touch-safe for panel installation, but not suitable for washdown environments without an additional enclosure.

Main current circuit terminals are screw-type, accepting solid conductors: 2× (0.5…1.5 mm²) and 2× (0.75…2.5 mm²). Stranded conductors: 2× (1…2.5 mm²) and 2× (2.5…6 mm²). This covers most motor feeder cables up to 6 mm². Auxiliary switch is transverse design, rated at 1 A at 24 V, 0.5 A at 230 V, and 0.15 A at 60 V — sufficient for signaling to a PLC input or contactor coil.

Shock resistance is 25g / 11 ms, suitable for machine-mounted applications with moderate vibration. Mechanical endurance of the main contacts is 100,000 operations typical; maximum switching frequency at AC-3 duty is 15 operations per hour.

Frequently asked questions

Where can I buy 3RV1021-0GA15-ZW97 and how do I get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What is 3RV1021-0GA15-ZW97's listed depth (96 mm) on this component line?

The depth is 96 mm. This is the dimension from the DIN rail mounting surface to the frontmost point of the breaker body — important for enclosure depth clearance.

What compliance documentation does this brand provide for 3RV1021-0GA15-ZW97 (RoHS, REACH, UL, IEC)?

As a Siemens SIRIUS product, the 3RV1021-0GA15-ZW97 is designed to meet IEC/EN 60947-2 and IEC/EN 60947-4-1 standards for motor protection circuit breakers. Siemens typically provides RoHS and REACH declarations on request through their documentation portal.

MPN
3RV1021-0GA15-ZW97