Siemens 3RV1021-0HA15-ZW95 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1021-0HA15-ZW95 SIRIUS Motor Protection Circuit B

MPN3RV1021-0HA15-ZW95

Siemens SIRIUS 3RV1021-0HA15-ZW95 motor protection circuit breaker, 0.8 A continuous, CLASS 10, 100 kA breaking capacity at 400 V AC, screw terminals, DIN rail mount.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3RV1021-0HA15-ZW95 — Identification
ParameterValue
SeriesSIRIUS
Product designationcircuit breaker

Electrical

3RV1021-0HA15-ZW95 — Electrical
ParameterValue
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated impulse withstand voltage (Uimp)6 000 V
Number of poles3
Power loss (AC, hot)7.25 W
Power loss, per pole (AC, hot)2.4 W

Protection & Tripping

3RV1021-0HA15-ZW95 — Protection & Tripping
ParameterValue
Overload release setting range0.55 ... 0.8 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)100 kA
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes

Endurance & Switching

3RV1021-0HA15-ZW95 — Endurance & Switching
ParameterValue
Auxiliary CO (changeover) contacts0

Connections

3RV1021-0HA15-ZW95 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementfront side
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor range, AWG (main contacts)2x (14 ... 10)

Mechanical

3RV1021-0HA15-ZW95 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth96 mm
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
Mounting positionany

Environmental

3RV1021-0HA15-ZW95 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Max. installation altitude2 000 m

Specifications

3RV1021-0HA15-ZW95 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

What it is and what it protects

The Siemens 3RV1021-0HA15-ZW95 is a SIRIUS motor-protection circuit breaker rated for 0.8 A continuous current with a CLASS 10 trip characteristic. It carries a 100 kA breaking capacity across the full AC voltage range from 240 V to 690 V, so it can safely interrupt a bolted fault at the motor terminals without the upstream breaker needing to clear it first — useful for high-fault-current panels. Phase failure detection is built in, so a single-phased motor will trip before the winding temperature climbs past the insulation class — a common failure mode on older three-phase lines.

Mounting and wiring

Mounts via screw and snap-on onto a 35 mm DIN rail per DIN EN 50022, and the 45 mm width means it occupies a single modular unit — no extra space needed for side or backward clearance (0 mm at the side, 0 mm backwards). Screw-type terminals on both main and auxiliary circuits accept solid conductors from 0.5 to 1.5 mm² (two per clamp) and stranded from 1 to 2.5 mm², with AWG equivalents for the main contacts at 2× (14…10). The auxiliary switch is transverse-mounted and field-addable — the product extension auxiliary switch is supported, so you can add a signal contact without replacing the breaker.

Environmental and lifecycle

Shock-rated to 25 g / 11 ms, and the IP20 front protection means it's suited for enclosed panel use only — not for washdown or outdoor exposure. RoHS compliance date is listed as 01.05.2012, so it meets the EU substance restrictions for current builds.

Sourcing and fit

If you are replacing a 3RV1011-0HA10 or 3RV1011-0GA10, the 3RV1021-0HA15-ZW95 shares the same 45 mm width, DIN rail mounting, and screw-terminal pattern, but the 0.8 A rating and CLASS 10 trip are specific — verify the motor FLA before swapping.

Frequently asked questions

Will 3RV1021-0HA15-ZW95 drop into a panel that was specified around 3RV1011-0HA10 without rewiring?

It shares the same 45 mm width, DIN rail mounting, and screw-terminal pattern, so the mechanical fit is the same. However, the 0.8 A continuous rating and CLASS 10 trip are specific to this variant — confirm the motor FLA matches before substituting.

What compliance documentation does this brand provide for 3RV1021-0HA15-ZW95?

RoHS compliance is documented with a substance prohibition date of 01.05.2012. The product also carries the SIRIUS brand designation and is designed to meet relevant IEC and UL standards for motor protection circuit breakers.