Skip to main content
Siemens 3RV1021-0JA10-0FJ0-ZX95 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1021-0JA10-0FJ0-ZX95 SIRIUS Motor Protection Circ

MPN3RV1021-0JA10-0FJ0-ZX95

Siemens SIRIUS motor protection circuit breaker, 3RV1021-0JA10-0FJ0-ZX95, 1 A rated continuous current, CLASS 10 trip class, 100 kA breaking capacity at 400 V AC, screw-type terminals, snap-on mounting.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3RV1021-0JA10-0FJ0-ZX95 — Identification
ParameterValue
SeriesSIRIUS
Product designationcircuit breaker

Electrical

3RV1021-0JA10-0FJ0-ZX95 — Electrical
ParameterValue
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated impulse withstand voltage (Uimp)6 000 V
Number of poles3
Power loss (AC, hot)7.25 W
Power loss, per pole (AC, hot)2.4 W

Protection & Tripping

3RV1021-0JA10-0FJ0-ZX95 — Protection & Tripping
ParameterValue
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)100 kA
Phase-failure detectionYes
Ground-fault detectionNo

Endurance & Switching

3RV1021-0JA10-0FJ0-ZX95 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h

Connections

3RV1021-0JA10-0FJ0-ZX95 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementfront side
Conductor cross-section, finely stranded with ferrule2x (1 ... 2.5 mm²), 2x (2.5 ... 6 mm²)

Mechanical

3RV1021-0JA10-0FJ0-ZX95 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth96 mm
Mounting positionany

Environmental

3RV1021-0JA10-0FJ0-ZX95 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C

Specifications

3RV1021-0JA10-0FJ0-ZX95 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

Motor protection circuit breaker, 1 A, CLASS 10 — SIRIUS 3RV1021

The Siemens 3RV1021-0JA10-0FJ0-ZX95 is a SIRIUS motor protection circuit breaker designed for motor protection duty. It carries a rated continuous current of 1 A and a CLASS 10 trip characteristic, meaning it will trip within 10 seconds at 7.2× the current setting — fast enough to protect standard induction motors during locked-rotor conditions without nuisance tripping on normal starts. Breaking capacity is 100 kA at 400 V AC (and across the full voltage range up to 690 V AC), so it can safely interrupt fault currents up to that level without upstream fuses or a larger breaker — a key advantage for panels with high available fault current. Phase failure detection is built in, so the breaker will trip if one phase is lost, preventing single-phasing damage to the motor. Ground fault detection is not included — that requires an external module or a separate ground-fault relay.

Mounting and panel integration

Mounts via screw or snap-on onto 35 mm DIN rail per DIN EN 50022. The 45 mm width means it occupies a single modular space — important for panel fill-factor planning. Any mounting position is allowed, so vertical or horizontal rail orientation is fine. Dimensions: 45 mm wide × 97 mm high × 96 mm deep. The 96 mm depth is the body depth behind the panel face — account for it when laying out gland plates and door clearance. Front face is IP20 — finger-safe but not washdown-rated. Suitable for enclosed panels only; not for outdoor or wet-area mounting without an additional enclosure.

Terminal and wiring details

Main circuit terminals are screw-type. Accepts solid or stranded conductors: 2× (1 … 2.5 mm²) or 2× (2.5 … 6 mm²) per terminal. AWG equivalents: 2× (14 … 10). Finely stranded conductors with core-end processing are also supported. No auxiliary contacts are included on this variant — an auxiliary switch block can be added if needed.

Environmental and endurance ratings

Operating temperature range: -20 to +60 °C; storage and transport: -50 to +80 °C. Maximum operating altitude: 2,000 m. Shock resistance: 25 g / 11 ms. Mechanical endurance of main contacts: 100,000 operations typical. Power dissipation at rated current in hot operating state: 7.25 W total, 2.4 W per pole. This matters for thermal management inside a sealed enclosure — account for the heat when sizing ventilation or cooling. Surge voltage resistance rated at 6,000 V — consistent with IEC 60947-2 overvoltage category III for industrial panels.

Lifecycle and sourcing

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing confirmed at quote time. For volume purchases or BOM-line commitments, submit an RFQ with target quantity and delivery window.

Frequently asked questions

What is the breaking capacity of 3RV1021-0JA10-0FJ0-ZX95?

Breaking capacity is 100 kA at 240 V, 400 V, 500 V, and 690 V AC — full rated capacity across the voltage range, so no derating needed at higher voltages.

What is the trip class of this circuit breaker?

Trip class is CLASS 10 — it will trip within 10 seconds at 7.2× the current setting, suitable for standard induction motor starting.

Does this breaker include phase failure protection?

Yes, phase failure detection is built in. Ground fault detection is not included.

Where can I buy 3RV1021-0JA10-0FJ0-ZX95 and how is it quoted?

This part is sourced and quoted to order against an RFQ through independent distribution. Submit an RFQ with your target quantity and delivery window for availability and current pricing.

MPN