Specifications

Identification

3RV1021-0JA15-ZW96 — Identification
ParameterValue
SeriesSIRIUS
Product designationcircuit breaker

Electrical

3RV1021-0JA15-ZW96 — Electrical
ParameterValue
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated impulse withstand voltage (Uimp)6 000 V
Number of poles3
Power loss (AC, hot)7.25 W
Power loss, per pole (AC, hot)2.4 W

Protection & Tripping

3RV1021-0JA15-ZW96 — Protection & Tripping
ParameterValue
Overload release setting range0.7 ... 1 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)100 kA
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes

Endurance & Switching

3RV1021-0JA15-ZW96 — Endurance & Switching
ParameterValue
Auxiliary CO (changeover) contacts0

Connections

3RV1021-0JA15-ZW96 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementfront side
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor range, AWG (main contacts)2x (14 ... 10)

Mechanical

3RV1021-0JA15-ZW96 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth96 mm
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
Mounting positionany

Environmental

3RV1021-0JA15-ZW96 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Max. installation altitude2 000 m

Specifications

3RV1021-0JA15-ZW96 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

Motor Protection Circuit Breaker for 1 A Loads

The Siemens SIRIUS 3RV1021-0JA15-ZW96 is a motor protection circuit breaker rated for 1 A continuous current with CLASS 10 trip characteristics, designed to protect motors up to 0.25 kW at 400 V AC. Its 100 kA breaking capacity at 400 V AC means it can safely interrupt fault currents up to that level without upstream fusing — a key spec for panel builders coordinating SCCR on a line-up. Mounts via screw and snap-on onto 35 mm DIN rail per EN 50022, with a 45 mm width footprint that fits standard panel layouts. The IP20 front protection is sufficient for enclosed control panels.

Termination and Wiring

Main circuit terminals accept screw-type connections: solid conductors 2x (0.5–1.5 mm²) and 2x (0.75–2.5 mm²); stranded conductors 2x (1–2.5 mm²) and 2x (2.5–6 mm²). AWG equivalents for main contacts are 2x (14–10). Auxiliary and control circuits also use screw-type terminals. The auxiliary switch is transverse design and is a product extension — the breaker accepts an add-on auxiliary switch block.

Environmental and Compliance

Operating temperature range is -20 to +60 °C; storage and transport range is -50 to +80 °C. Shock resistance rated at 25g / 11 ms. Mounting position is any orientation. RoHS compliance date is 01.05.2012 — the part meets the RoHS substance prohibitions effective from that date. Phase failure detection is built in; ground fault detection is not.

Frequently asked questions

Does 3RV1021-0JA15-ZW96 have phase failure protection?

Yes, phase failure detection is built in. Ground fault detection is not included.

MPN