Skip to main content
Siemens 3RV1021-0JA15-ZX95 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1021-0JA15-ZX95 SIRIUS Motor Protection Circuit B

MPN3RV1021-0JA15-ZX95

Siemens SIRIUS motor protection circuit breaker, 3RV1021-0JA15-ZX95, rated 1 A continuous, Class 10 trip, 100 kA breaking capacity at 400 V AC, screw terminals, 45 mm wide.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV1021-0JA15-ZX95 — Identification
ParameterValue
SeriesSIRIUS
Product designationcircuit breaker
3RV1021-0JA15-ZX95 — Electrical
ParameterValue
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated impulse withstand voltage (Uimp)6 000 V
Number of poles3
Power loss (AC, hot)7.25 W
Power loss, per pole (AC, hot)2.4 W
3RV1021-0JA15-ZX95 — Protection & Tripping
ParameterValue
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)100 kA
Phase-failure detectionYes
Ground-fault detectionNo
3RV1021-0JA15-ZX95 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
3RV1021-0JA15-ZX95 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementfront side
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
3RV1021-0JA15-ZX95 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth96 mm
Mounting positionany
3RV1021-0JA15-ZX95 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
3RV1021-0JA15-ZX95 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

It carries a 1 A continuous current rating and a Class 10 trip characteristic, meaning it will disconnect within 10 seconds at 7.2× the set current — fast enough to protect a standard induction motor during a locked-rotor event without nuisance tripping on startup inrush. The interrupting rating is a flat 100 kA across all common industrial voltages (240 V, 400 V, 500 V, 690 V AC), so it handles high available fault current without cascading upstream breakers.

The 45 mm width keeps the footprint tight in a multi-device motor control center. Screw-type terminals on the main circuit accept stranded conductors up to 2x 6 mm² or solid up to 2x 2.5 mm², so it handles standard motor feeder cables without adapters. Auxiliary contacts are transverse design, with space for one block. Clearances: zero mm required at the rear or sides, so you can butt-mount these against other devices on the rail. Front face is IP20 — finger-safe for panel access, but keep it inside an enclosure. Shock rated at 25g for 11 ms, which covers most conveyor and pump vibration environments.

Frequently asked questions

Where can I buy 3RV1021-0JA15-ZX95?

This part is sourced through independent distribution and quoted to order against an RFQ. Availability and pricing are confirmed at quote time.

What is the closest functional alternative to 3RV1021-0JA15-ZX95?

The 3RV1011-0GA10 is a smaller-frame SIRIUS motor protection breaker with a lower breaking capacity and narrower width. It will not drop into a panel wired for the 3RV1021 without checking the terminal capacity and fault-current coordination — the 3RV1021 carries a 100 kA rating across all voltages, while the 3RV1011 frame is typically rated lower.

What is the depth of 3RV1021-0JA15-ZX95?

The depth is 96 mm, with a width of 45 mm and height of 97 mm.

What wire sizes does the 3RV1021-0JA15-ZX95 accept?

Solid conductors: 2x (0.5 to 1.5 mm²) and 2x (0.75 to 2.5 mm²). Stranded: 2x (1 to 2.5 mm²) and 2x (2.5 to 6 mm²).

MPN
3RV1021-0JA15-ZX95