Siemens 3RV1021-0KA15 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1021-0KA15 SIRIUS Motor Protection CB, 1.25 A, Cl

MPN3RV1021-0KA15

Siemens SIRIUS motor protection circuit breaker, 3RV1021-0KA15, 1.25 A continuous rated current, Class 10 trip class, 100 kA breaking capacity at 400 V AC, screw-type terminals, snap-on DIN rail mounting.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3RV1021-0KA15 — Identification
ParameterValue
SeriesSIRIUS
Product designationcircuit breaker

Electrical

3RV1021-0KA15 — Electrical
ParameterValue
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated impulse withstand voltage (Uimp)6 000 V
Number of poles3
Power loss (AC, hot)7.25 W
Power loss, per pole (AC, hot)2.4 W

Protection & Tripping

3RV1021-0KA15 — Protection & Tripping
ParameterValue
Overload release setting range0.9 ... 1.25 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)100 kA
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes

Endurance & Switching

3RV1021-0KA15 — Endurance & Switching
ParameterValue
Auxiliary CO (changeover) contacts0

Connections

3RV1021-0KA15 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementfront side
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor range, AWG (main contacts)2x (14 ... 10)

Mechanical

3RV1021-0KA15 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth96 mm
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
Mounting positionany

Environmental

3RV1021-0KA15 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Max. installation altitude2 000 m

Specifications

3RV1021-0KA15 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

SIRIUS 3RV1021-0KA15 — Motor Protection Circuit Breaker, 1.25 A

The Siemens 3RV1021-0KA15 is a SIRIUS motor protection circuit breaker rated for 1.25 A continuous current with a Class 10 trip characteristic, meaning it protects motors against overload and short circuit by tripping within 10 seconds at 7.2× rated current — fast enough for standard induction motor starts without nuisance tripping. Rated for 690 V AC maximum, it delivers 100 kA breaking capacity across 240 V, 400 V, 500 V, and 690 V AC — sufficient to clear high-fault-current scenarios in industrial distribution without cascading upstream breakers. Mounts via screw or snap-on onto 35 mm DIN rail per EN 50022, with a 45 mm width footprint that fits standard panel layout grids. IP20 front protection means it is touch-safe for the panel interior but not rated for washdown environments.

Motor Duty and Trip Coordination

At 400 V AC-3 duty, this breaker supports a 0.37 kW motor load — the rating that governs real-world motor protection sizing, not the 1.25 A continuous current alone. The 1.25 A continuous rating sets the thermal overload threshold; the 0.37 kW figure tells you what motor frame it protects on a 400 V line. Phase failure detection is built in, so a lost phase on the supply side will trip the breaker — critical for preventing single-phasing damage on delta-connected motors. No ground fault detection, so that function must be handled separately downstream. Power dissipation at rated current in hot operating state is 7.25 W — factor this into enclosure thermal calculations if multiple breakers are ganged in a small cabinet.

Termination and Wiring

Main circuit terminals accept screw-type connections: solid conductors from 2x (0.5 to 1.5 mm²) up to 2x (0.75 to 2.5 mm²), and stranded conductors from 2x (1 to 2.5 mm²) up to 2x (2.5 to 6 mm²). AWG equivalents for main contacts are 2x (14 to 10). Auxiliary and control circuits also use screw terminals. Auxiliary switch extension is available as a product option, with a transverse design — allows adding a signal contact for remote status indication without replacing the breaker.

Environmental and Mechanical

Operating temperature range is -20 to +60 °C; storage and transport range is -50 to +80 °C. Shock resistance rated at 25 g for 11 ms — suitable for installation on machinery subject to vibration, such as conveyor drives or compressor skids. Mounting position is any orientation, and backwards and side clearances are 0 mm — meaning no mandatory air gap to adjacent devices, simplifying panel layout.

Frequently asked questions

What is the breaking capacity of 3RV1021-0KA15 at 400 V?

It delivers 100 kA breaking capacity at 400 V AC, the same rating as at 240 V, 500 V, and 690 V AC.

Will 3RV1021-0KA15 drop into a panel specified around 3RV1011-0HA10?

Both are SIRIUS motor protection breakers with similar DIN rail mounting, but the 3RV1011-0HA10 has different current ratings and trip characteristics — verify the continuous current and motor power rating against your load before substituting.

What compliance documentation does Siemens provide for 3RV1021-0KA15?

The product carries a substance prohibitance date of 05/01/2012, indicating RoHS compliance. Standard Siemens documentation includes the declaration of conformity for the relevant EU directives (Low Voltage, EMC) and the manufacturer's declaration for UL/CSA listing where applicable.

Where can I buy 3RV1021-0KA15 and how is it quoted?

This part is sourced and quoted to order against an RFQ through independent industrial automation distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commercial offer.

MPN
3RV1021-0KA15