Siemens 3RV1021-1AA10-0FJ0-ZX95 — Motor Protection Circuit Breakers (MPCB)

Siemens SIRIUS 3RV1021-1AA10-0FJ0-ZX95 motor-protection circ

MPN3RV1021-1AA10-0FJ0-ZX95

Siemens SIRIUS 3RV1021-1AA10-0FJ0-ZX95, motor-protection circuit breaker, 1.6 A rated continuous current, CLASS 10 trip class, 100 kA breaking capacity at 400 V AC, screw terminals, DIN-rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3RV1021-1AA10-0FJ0-ZX95 — Identification
ParameterValue
SeriesSIRIUS
Product designationcircuit breaker
3RV1021-1AA10-0FJ0-ZX95 — Electrical
ParameterValue
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated impulse withstand voltage (Uimp)6 000 V
Number of poles3
Power loss (AC, hot)7.25 W
Power loss, per pole (AC, hot)2.4 W
3RV1021-1AA10-0FJ0-ZX95 — Protection & Tripping
ParameterValue
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)100 kA
Phase-failure detectionYes
Ground-fault detectionNo
3RV1021-1AA10-0FJ0-ZX95 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
3RV1021-1AA10-0FJ0-ZX95 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementfront side
Conductor cross-section, finely stranded with ferrule2x (1 ... 2.5 mm²), 2x (2.5 ... 6 mm²)
3RV1021-1AA10-0FJ0-ZX95 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth96 mm
Mounting positionany
3RV1021-1AA10-0FJ0-ZX95 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
3RV1021-1AA10-0FJ0-ZX95 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

The Siemens SIRIUS 3RV1021-1AA10-0FJ0-ZX95 is a motor-protection circuit breaker rated for 1.6 A continuous current with a CLASS 10 trip characteristic, meaning it will trip within 10 seconds at 7.2× rated current — fast enough to protect standard induction motors during stall or overload without nuisance tripping on normal starting inrush.

Compared to the 3RV1011-0GA10 (a physically smaller frame in the same SIRIUS family), the 3RV1021-1AA10-0FJ0-ZX95 offers the same CLASS 10 trip and 100 kA SCCR but at a higher continuous current rating — 1.6 A versus 0.4 A — and with a wider conductor range (up to 6 mm² vs 2.5 mm²). The 45 mm width is identical, so a panel designed around the 3RV1011 frame accepts this unit without rewiring the DIN rail.

IP20 finger-safe on the front; no special clearance needed at the sides or rear. Ground fault detection is not included — this is a motor-overload and short-circuit device, not a GFCI.

Frequently asked questions

What is the breaking capacity of 3RV1021-1AA10-0FJ0-ZX95 at 400 V AC?

100 kA at 400 V AC, and the same 100 kA rating holds at 240 V, 500 V, and 690 V AC.

Will 3RV1021-1AA10-0FJ0-ZX95 drop into a panel specified for 3RV1011-0GA10 without rewiring?

Yes — both units share the same 45 mm width and DIN-rail footprint, so the mechanical fit is identical. The 3RV1021 carries a higher continuous current (1.6 A vs 0.4 A) and accepts larger conductors (up to 6 mm²), but the rail position and terminal pitch are the same.

Where can I buy 3RV1021-1AA10-0FJ0-ZX95 and how is it quoted?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

MPN
3RV1021-1AA10-0FJ0-ZX95