Siemens 3RV1021-1AA10-ZW96 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1021-1AA10-ZW96 SIRIUS Motor Protection CB, 1.6 A

MPN3RV1021-1AA10-ZW96

Siemens SIRIUS 3RV1021-1AA10-ZW96, motor protection circuit breaker, 1.6 A, Trip Class 10, 3-pole, 100 kA breaking capacity at 400 V, screw terminals, snap-on DIN rail.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3RV1021-1AA10-ZW96 — Identification
ParameterValue
SeriesSIRIUS
Product designationcircuit breaker
3RV1021-1AA10-ZW96 — Electrical
ParameterValue
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated impulse withstand voltage (Uimp)6 000 V
Number of poles3
Power loss (AC, hot)7.25 W
Power loss, per pole (AC, hot)2.4 W
3RV1021-1AA10-ZW96 — Protection & Tripping
ParameterValue
Overload release setting range1.1 ... 1.6 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)100 kA
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV1021-1AA10-ZW96 — Endurance & Switching
ParameterValue
Auxiliary CO (changeover) contacts0
3RV1021-1AA10-ZW96 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementfront side
Conductor cross-section, finely stranded with ferrule2x (1 ... 2.5 mm²), 2x (2.5 ... 6 mm²)
Conductor range, AWG (main contacts)2x (14 ... 10)
3RV1021-1AA10-ZW96 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth96 mm
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
Mounting positionany
3RV1021-1AA10-ZW96 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Max. installation altitude2 000 m
3RV1021-1AA10-ZW96 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

The 3RV1021-1AA10-ZW96: The 1.6 A continuous rating and 0.55 kW motor power at 400 V AC size this breaker for small motors—pumps, fans, conveyors up to that load. No ground-fault detection on this variant; if that's needed, you'd step to a different suffix or add an external module.

The 45 mm width means it takes one standard 45 mm-wide slot in a panel—no extra side clearance needed (0 mm at the side,). Wire range: solid or stranded 1–2.5 mm² (two conductors) and 2.5–6 mm² (two conductors) per terminal. That covers most motor-circuit wiring up to 6 mm². IP20 front protection means it's safe for finger contact in a closed panel but not for washdown environments.

Frequently asked questions

What is the breaking capacity of this breaker?

100 kA at 240 V, 400 V, 500 V, and 690 V AC (–). That's a high-interrupting rating for a 1.6 A frame, suitable for high-fault-current installations.

Will the 3RV1021-1AA10-ZW96 drop into a panel built for the 3RV1011-0HA10?

Both are 45 mm wide, 3-pole SIRIUS breakers with screw terminals and snap-on DIN rail mounting, so the footprint and wiring are the same. The key difference is the continuous current rating—1.6 A on this part versus the 3RV1011-0HA10's rating. Check your motor FLA before swapping.