Siemens SIRIUS 3RV1021-1AA15-ZW95 motor-protective circuit breaker, 1.6 A continuous current, Class 10 trip, 100 kA breaking capacity at 400 V AC, screw terminals, IP20 front.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV1021-1AA15-ZW95 — Identification
ParameterValue
SeriesSIRIUS
Product designationcircuit breaker
3RV1021-1AA15-ZW95 — Electrical
ParameterValue
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated impulse withstand voltage (Uimp)6 000 V
Number of poles3
Power loss (AC, hot)7.25 W
Power loss, per pole (AC, hot)2.4 W
3RV1021-1AA15-ZW95 — Protection & Tripping
ParameterValue
Overload release setting range1.1 ... 1.6 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)100 kA
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV1021-1AA15-ZW95 — Endurance & Switching
ParameterValue
Auxiliary CO (changeover) contacts0
3RV1021-1AA15-ZW95 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementfront side
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor range, AWG (main contacts)2x (14 ... 10)
3RV1021-1AA15-ZW95 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth96 mm
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
Mounting positionany
3RV1021-1AA15-ZW95 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Max. installation altitude2 000 m
3RV1021-1AA15-ZW95 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

Motor-protective breaker, 1.6 A, Class 10 — the line-down spare

The Siemens 3RV1021-1AA15-ZW95 is a SIRIUS motor-protective circuit breaker sized for a 0.55 kW motor at 400 V, with a continuous current rating of 1.6 A and Trip Class 10 — meaning it trips fast enough to protect standard induction motors during locked-rotor conditions without nuisance tripping on normal starts. Breaking capacity hits 100 kA at 240 V, 400 V, 500 V, and 690 V AC — that's full-range fault clearing without needing an upstream current-limiting fuse in most industrial panels, as long as the prospective short-circuit current stays under that threshold. No ground-fault sensing here — that's handled separately downstream if needed.

Mounting and wiring — DIN rail, any position, screw terminals

Main circuit screw terminals accept 2x (0.5…1.5 mm²) solid or 2x (1…2.5 mm²) stranded; auxiliary/control circuit terminals take 2x (0.75…2.5 mm²) solid. AWG equivalents for the main contacts are 2x (14…10). Zero clearance needed at the back or sides for cooling.

Environmental and lifecycle — current production, wide temperature range

Shock rated at 25g for 11 ms.