Siemens 3RV1021-1AA15-ZX95 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1021-1AA15-ZX95 SIRIUS Motor Protection CB, 1.6 A

MPN3RV1021-1AA15-ZX95

Siemens SIRIUS motor protection circuit breaker, 3RV1021-1AA15-ZX95, 1.6 A rated current, Class 10 trip, 100 kA breaking capacity, screw terminals, 45 mm width.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV1021-1AA15-ZX95 — Identification
ParameterValue
SeriesSIRIUS
Product designationcircuit breaker
3RV1021-1AA15-ZX95 — Electrical
ParameterValue
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated impulse withstand voltage (Uimp)6 000 V
Number of poles3
Power loss (AC, hot)7.25 W
Power loss, per pole (AC, hot)2.4 W
3RV1021-1AA15-ZX95 — Protection & Tripping
ParameterValue
Overload release setting range1.1 ... 1.6 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)100 kA
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV1021-1AA15-ZX95 — Endurance & Switching
ParameterValue
Auxiliary CO (changeover) contacts0
3RV1021-1AA15-ZX95 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementfront side
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor range, AWG (main contacts)2x (14 ... 10)
3RV1021-1AA15-ZX95 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth96 mm
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
Mounting positionany
3RV1021-1AA15-ZX95 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Max. installation altitude2 000 m
3RV1021-1AA15-ZX95 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

The Siemens 3RV1021-1AA15-ZX95 is a SIRIUS motor protection circuit breaker sized for a 1.6 A continuous current and rated for a 0.55 kW motor at 400 V AC. That 1.6 A is the full-load ampacity it carries without tripping — bump the load beyond that and the Class 10 bimetal curve starts its clock, opening in under 10 seconds at 7.2× rated current. Class 10 is the standard for standard induction motors; it protects the winding before the rotor stalls and cooks the insulation. The 100 kA breaking capacity holds across the full voltage range — 240 V, 400 V, 500 V, and 690 V AC — so this breaker clears a bolted fault upstream of the motor starter without welding its contacts shut. If one leg of a three-phase supply drops out, the breaker trips — that's a real help on a motor line where a single-phased winding can burn out before the overload relay notices. No ground-fault detection here, so keep a separate GFCI or RCD in the circuit if the installation code requires it.

Mount it in any position — vertical, horizontal, upside-down — the thermal curve doesn't care. Screw terminals on both the main and auxiliary circuits. The main terminals accept solid wire from 0.5 to 1.5 mm² (two per clamp) and stranded from 1.0 to 2.5 mm² (two per clamp). For the auxiliary / control circuit, the same terminal range applies. AWG 14 to 10 on the main contacts. That's enough for the 1.6 A motor branch plus a small control transformer downstream.

Frequently asked questions

What is the breaking capacity of this breaker?

100 kA at 240 V, 400 V, 500 V, and 690 V AC — a high-fault rating that lets it sit on a high-capacity bus without upstream fusing.

Where can I buy 3RV1021-1AA15-ZX95?

This part is sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time.

Does it have phase failure protection?

Yes, phase failure detection is built in — it trips if one supply leg drops out, protecting the motor from single-phasing.

What is the operating frequency limit?

Maximum 15 switching operations per hour in AC-3 duty — sized for a motor start cycle, not for rapid jogging or inching.

MPN
3RV1021-1AA15-ZX95