Skip to main content
Siemens 3RV1021-1BA10-ZW97 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1021-1BA10-ZW97 SIRIUS Motor Protection Circuit B

MPN3RV1021-1BA10-ZW97

Siemens SIRIUS motor protection circuit breaker, 3RV1021-1BA10-ZW97, 2 A continuous, Class 10, 100 kA at 400 V AC, screw terminals, 45 mm wide.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV1021-1BA10-ZW97 — Identification
ParameterValue
SeriesSIRIUS
Product designationcircuit breaker
3RV1021-1BA10-ZW97 — Electrical
ParameterValue
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated impulse withstand voltage (Uimp)6 000 V
Number of poles3
Power loss (AC, hot)7.25 W
Power loss, per pole (AC, hot)2.4 W
3RV1021-1BA10-ZW97 — Protection & Tripping
ParameterValue
Overload release setting range1.4 ... 2 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)8 kA
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV1021-1BA10-ZW97 — Endurance & Switching
ParameterValue
Auxiliary CO (changeover) contacts0
3RV1021-1BA10-ZW97 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementfront side
Conductor cross-section, finely stranded with ferrule2x (1 ... 2.5 mm²), 2x (2.5 ... 6 mm²)
Conductor range, AWG (main contacts)2x (14 ... 10)
3RV1021-1BA10-ZW97 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth96 mm
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
Mounting positionany
3RV1021-1BA10-ZW97 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Max. installation altitude2 000 m
3RV1021-1BA10-ZW97 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

What this SIRIUS breaker does on the line

Snaps onto 35 mm DIN rail per DIN EN 50022, or screws direct to a backplate — 45 mm wide, 97 mm tall, 96 mm deep, so it takes one standard 45 mm slot in a motor control center. Screw terminals on both main and auxiliary circuits accept 1 to 2.5 mm² solid or stranded (two wires per clamp), or 2.5 to 6 mm² for heavier feeds — no special crimp tool needed. IP20 on the front face keeps fingers out; the rest of the breaker is inside the enclosure, so no washdown rating — this lives in a dry cabinet.

Frequently asked questions

What is 3RV1021-1BA10-ZW97's listed depth?

96 mm deep, 45 mm wide, 97 mm tall — fits a standard 45 mm DIN-rail slot.

What compliance documentation does this brand provide for 3RV1021-1BA10-ZW97?

RoHS compliance date is 01.05.2012; the breaker carries IEC and UL ratings for motor protection duty.

MPN
3RV1021-1BA10-ZW97