Skip to main content
Siemens 3RV1021-1CA10-0FJ0-ZX95 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1021-1CA10-0FJ0-ZX95 SIRIUS Motor Protection Circ

MPN3RV1021-1CA10-0FJ0-ZX95

Siemens SIRIUS, motor protection circuit breaker, order code 3RV1021-1CA10-0FJ0-ZX95, 2.5 A continuous current, CLASS 10 trip, 100 kA breaking capacity at 400 V AC, screw-type terminals, DIN rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3RV1021-1CA10-0FJ0-ZX95 — Identification
ParameterValue
SeriesSIRIUS
Product designationcircuit breaker
3RV1021-1CA10-0FJ0-ZX95 — Electrical
ParameterValue
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated impulse withstand voltage (Uimp)6 000 V
Number of poles3
Power loss (AC, hot)7.25 W
Power loss, per pole (AC, hot)2.4 W
3RV1021-1CA10-0FJ0-ZX95 — Protection & Tripping
ParameterValue
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)8 kA
Phase-failure detectionYes
Ground-fault detectionNo
3RV1021-1CA10-0FJ0-ZX95 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
3RV1021-1CA10-0FJ0-ZX95 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementfront side
Conductor cross-section, finely stranded with ferrule2x (1 ... 2.5 mm²), 2x (2.5 ... 6 mm²)
3RV1021-1CA10-0FJ0-ZX95 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth96 mm
Mounting positionany
3RV1021-1CA10-0FJ0-ZX95 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
3RV1021-1CA10-0FJ0-ZX95 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

The Siemens SIRIUS 3RV1021-1CA10-0FJ0-ZX95 is a motor protection circuit breaker rated for 2.5 A continuous current, with a CLASS 10 trip characteristic and a 100 kA breaking capacity at 400 V AC — enough to handle high-fault utility feeds without cascading upstream. It includes phase failure detection, so a lost phase on the line side trips the breaker before the motor single-phases and burns out. Terminals are screw-type for the main circuit, accepting solid or stranded conductors up to 6 mm².

The 2.5 A continuous rating sets the motor FLA it can protect — pair it with a motor drawing up to 2.5 A full-load. CLASS 10 trip means it opens within 10 seconds at 7.2× rated current, matching standard induction-motor starting profiles. 100 kA breaking capacity at 400 V AC (and also at 240 V and 500 V) means it safely interrupts faults up to that level without needing a backup fuse for most industrial supplies. At 690 V the breaking capacity drops to 8 kA — still adequate for 690 V systems with limited fault current. IP20 on the front, open-type otherwise — intended for enclosure mounting, not exposed outdoor use.

Frequently asked questions

What is the listed depth of 3RV1021-1CA10-0FJ0-ZX95?

The depth is 96 mm, with a width of 45 mm and height of 97 mm — fits standard 45 mm wide DIN-rail footprint.

Does 3RV1021-1CA10-0FJ0-ZX95 include phase failure detection?

Yes, it has built-in phase failure detection, so a lost phase causes the breaker to trip and protect the motor.

What compliance documentation does Siemens provide for this part?

As a Siemens SIRIUS product, this circuit breaker carries CE, UL, CSA, and CCC approvals per standard Siemens documentation. Specific certificates are available on request.

MPN
3RV1021-1CA10-0FJ0-ZX95