Siemens 3RV1021-1CA10-ZW96 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1021-1CA10-ZW96 SIRIUS Motor Protection Circuit B

MPN3RV1021-1CA10-ZW96

Siemens SIRIUS, motor protection circuit breaker, 3RV1021-1CA10-ZW96, 2.5 A continuous rated current, Trip Class 10, 100 kA breaking capacity at 400 V AC, screw terminals, IP20 front, DIN-rail mount.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3RV1021-1CA10-ZW96 — Identification
ParameterValue
SeriesSIRIUS
Product designationcircuit breaker

Electrical

3RV1021-1CA10-ZW96 — Electrical
ParameterValue
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated impulse withstand voltage (Uimp)6 000 V
Number of poles3
Power loss (AC, hot)7.25 W
Power loss, per pole (AC, hot)2.4 W

Protection & Tripping

3RV1021-1CA10-ZW96 — Protection & Tripping
ParameterValue
Overload release setting range1.8 ... 2.5 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)8 kA
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes

Endurance & Switching

3RV1021-1CA10-ZW96 — Endurance & Switching
ParameterValue
Auxiliary CO (changeover) contacts0

Connections

3RV1021-1CA10-ZW96 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementfront side
Conductor cross-section, finely stranded with ferrule2x (1 ... 2.5 mm²), 2x (2.5 ... 6 mm²)
Conductor range, AWG (main contacts)2x (14 ... 10)

Mechanical

3RV1021-1CA10-ZW96 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth96 mm
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
Mounting positionany

Environmental

3RV1021-1CA10-ZW96 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Max. installation altitude2 000 m

Specifications

3RV1021-1CA10-ZW96 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

The Siemens 3RV1021-1CA10-ZW96 is a SIRIUS motor protection circuit breaker rated for 2.5 A continuous current with Trip Class 10 thermal overload protection. It provides 100 kA breaking capacity at 400 V AC, covering the most common industrial supply voltage for motor branch circuits. Phase failure detection is built in, so a lost phase trips the breaker before the motor single-phases and burns out.

Mounts via screw and snap-on onto 35 mm standard mounting rail per DIN EN 50022. Width is 45 mm, height 97 mm, depth 96 mm — fits a standard 3-pole MCCB footprint on the rail. IP20 on the front means it's protected against finger contact but not washdown; install inside a rated enclosure. Screw-type terminals for main and auxiliary circuits accept 2x (1...2.5 mm²) solid or stranded, and 2x (2.5...6 mm²) — no special lug kit needed for the larger wire.

Frequently asked questions

What wire sizes fit the terminals on 3RV1021-1CA10-ZW96?

Screw terminals accept 2x (1...2.5 mm²) and 2x (2.5...6 mm²) for both solid and stranded conductors.

Does 3RV1021-1CA10-ZW96 include phase failure protection?

Yes, phase failure detection is built in — it trips the breaker if one phase is lost, preventing motor damage from single-phasing.

MPN
3RV1021-1CA10-ZW96