Siemens 3RV1021-1CA15-ZW95 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1021-1CA15-ZW95 SIRIUS Motor Protection Circuit B

MPN3RV1021-1CA15-ZW95

Siemens SIRIUS motor protection circuit breaker, 3RV1021-1CA15-ZW95, 2.5 A continuous rated current, Class 10 trip, 100 kA breaking capacity at 400 V AC, screw-type terminals, snap-on 35 mm DIN rail mounting.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV1021-1CA15-ZW95 — Identification
ParameterValue
SeriesSIRIUS
Product designationcircuit breaker
3RV1021-1CA15-ZW95 — Electrical
ParameterValue
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated impulse withstand voltage (Uimp)6 000 V
Number of poles3
Power loss (AC, hot)7.25 W
Power loss, per pole (AC, hot)2.4 W
3RV1021-1CA15-ZW95 — Protection & Tripping
ParameterValue
Overload release setting range1.8 ... 2.5 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)8 kA
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV1021-1CA15-ZW95 — Endurance & Switching
ParameterValue
Auxiliary CO (changeover) contacts0
3RV1021-1CA15-ZW95 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementfront side
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor range, AWG (main contacts)2x (14 ... 10)
3RV1021-1CA15-ZW95 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth96 mm
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
Mounting positionany
3RV1021-1CA15-ZW95 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Max. installation altitude2 000 m
3RV1021-1CA15-ZW95 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

It carries a continuous rated current of 2.5 A and trips under Class 10 overload protection, meaning it clears a stalled-rotor condition within 10 seconds at 7.2× Ie — fast enough to protect a standard induction motor winding before insulation damage sets in.

The high 100 kA rating holds through 500 V, so it coordinates cleanly with upstream fuses or a moulded-case breaker without requiring a current-limiting device.

The 45 mm width takes one standard DIN slot. Main circuit terminals accept 2x (1... 2.5 mm²) stranded or 2x (0.75... 2.5 mm²) solid; auxiliary and control circuit terminals are screw-type as well. Zero clearance needed at the sides or rear — stack them tight in a panel.

Auxiliary switch and environmental limits

The product extension auxiliary switch is transverse-designed and rated at 1 A at 24 V, 0.5 A at 230 V, and 0.15 A at 60 V — enough to signal a trip back to a PLC input or a status lamp. Shock resistance is 25 g for 11 ms. IP20 on the front face keeps fingers out but the breaker is intended for inside an enclosure, not exposed.

Frequently asked questions

What is the breaking capacity of 3RV1021-1CA15-ZW95 at 400 V?

100 kA at 400 V AC, which holds through 500 V. At 690 V AC it derates to 8 kA.

What does Class 10 trip mean for motor protection?

Class 10 means the breaker will trip within 10 seconds at 7.2 times the rated current, protecting standard induction motor windings from thermal damage during a stalled rotor or locked-rotor condition.

Where can I get pricing and availability for 3RV1021-1CA15-ZW95?

This part is sourced and quoted to order against an RFQ through independent distribution. Current pricing and availability are confirmed at quote time.

MPN
3RV1021-1CA15-ZW95