Siemens SIRIUS motor protection circuit breaker, 3RV1021-1CA15-ZX95, 2.5 A continuous rated current, 0.75 kW at 400 V, Trip Class 10, screw-type terminals, IP20 front.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3RV1021-1CA15-ZX95 — Identification
ParameterValue
SeriesSIRIUS
Product designationcircuit breaker

Electrical

3RV1021-1CA15-ZX95 — Electrical
ParameterValue
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated impulse withstand voltage (Uimp)6 000 V
Number of poles3
Power loss (AC, hot)7.25 W
Power loss, per pole (AC, hot)2.4 W

Protection & Tripping

3RV1021-1CA15-ZX95 — Protection & Tripping
ParameterValue
Overload release setting range1.8 ... 2.5 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)8 kA
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes

Endurance & Switching

3RV1021-1CA15-ZX95 — Endurance & Switching
ParameterValue
Auxiliary CO (changeover) contacts0

Connections

3RV1021-1CA15-ZX95 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementfront side
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor range, AWG (main contacts)2x (14 ... 10)

Mechanical

3RV1021-1CA15-ZX95 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth96 mm
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
Mounting positionany

Environmental

3RV1021-1CA15-ZX95 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Max. installation altitude2 000 m

Specifications

3RV1021-1CA15-ZX95 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

Motor protection circuit breaker, 2.5 A, Trip Class 10

The Siemens 3RV1021-1CA15-ZX95 is a SIRIUS motor protection circuit breaker rated for 2.5 A continuous current and 0.75 kW at 400 V AC-3 duty, with a Trip Class 10 thermal overload curve. It's designed for motor protection in control panels, with screw-type terminals for main and auxiliary circuits. The unit mounts via screw or snap-on onto 35 mm DIN rail per EN 50022, and the front face carries IP20 protection.

Breaking capacity and coordination

Breaking capacity reaches 100 kA at 240 V, 400 V, and 500 V AC, dropping to 8 kA at 690 V AC. That 100 kA at 400 V means it can interrupt high fault currents typical in industrial distribution without upstream devices needing to clear the fault — useful for Type 2 coordination with contactors downstream. The 8 kA at 690 V still covers most motor branch circuits at that voltage level.

Lifecycle and sourcing

This part carries a current production lifecycle status. It's sourced and quoted to order against an RFQ through independent distribution channels; availability and current pricing are confirmed at quote time. The RoHS compliance date is 01.05.2012, meaning it meets the EU RoHS directive for substances of concern.

Mounting and wiring

Mounts in any position on 35 mm DIN rail per EN 50022, with zero clearance needed at the sides or rear. Main circuit terminals accept solid conductors 2x (0.5...1.5 mm²) and 2x (0.75...2.5 mm²), or stranded 2x (1...2.5 mm²) and 2x (2.5...6 mm²). Auxiliary and control circuit terminals are also screw-type. The auxiliary switch is transverse design and field-installable.

Environmental and operational limits

Operating temperature range is -20 to +60 °C, storage and transport range -50 to +80 °C. Shock resistance is 25 g for 11 ms. The unit has phase failure detection but no ground fault detection. Power dissipation in hot operating state is 7.25 W at rated current.

Frequently asked questions

Where can I buy 3RV1021-1CA15-ZX95 and get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Submit an RFQ for current availability and pricing — confirmed at quote time.

What is the breaking capacity of 3RV1021-1CA15-ZX95 at 400 V?

100 kA at 400 V AC, which is the same rating at 240 V and 500 V. At 690 V it drops to 8 kA.

What wire sizes does the 3RV1021-1CA15-ZX95 accept?

Main terminals accept solid 2x (0.5...1.5 mm²) and 2x (0.75...2.5 mm²), or stranded 2x (1...2.5 mm²) and 2x (2.5...6 mm²). AWG equivalents for main contacts are 2x (14...10).

Does 3RV1021-1CA15-ZX95 have phase failure protection?

Yes, it includes phase failure detection. It does not include ground fault detection.

MPN