Siemens 3RV1021-1DA15-ZW98 — Motor Protection Circuit Breakers (MPCB)

Siemens SIRIUS 3RV1021-1DA15-ZW98 Motor Protection Circuit B

MPN3RV1021-1DA15-ZW98

Siemens SIRIUS 3RV1021-1DA15-ZW98, motor protection circuit breaker, 3.2 A continuous, Class 10 trip, 100 kA breaking at 400 V AC, screw and snap-on DIN rail mount.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3RV1021-1DA15-ZW98 — Identification
ParameterValue
SeriesSIRIUS
Product designationcircuit breaker

Electrical

3RV1021-1DA15-ZW98 — Electrical
ParameterValue
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated impulse withstand voltage (Uimp)6 000 V
Number of poles3
Power loss (AC, hot)7.25 W
Power loss, per pole (AC, hot)2.4 W

Protection & Tripping

3RV1021-1DA15-ZW98 — Protection & Tripping
ParameterValue
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)8 kA
Phase-failure detectionYes
Ground-fault detectionNo

Endurance & Switching

3RV1021-1DA15-ZW98 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h

Connections

3RV1021-1DA15-ZW98 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementfront side
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)

Mechanical

3RV1021-1DA15-ZW98 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth96 mm
Mounting positionany

Environmental

3RV1021-1DA15-ZW98 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C

Specifications

3RV1021-1DA15-ZW98 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

What this 3.2 A motor protection breaker is and what it does

The Siemens SIRIUS 3RV1021-1DA15-ZW98 is a motor protection circuit breaker rated for 3.2 A continuous current and a 1.1 kW motor at 400 V AC, with a Class 10 trip characteristic — meaning it clears overloads fast enough to protect standard induction motors during start-up without nuisance tripping. It mounts via screw or snap-on onto 35 mm DIN rail per EN 50022, occupies 45 mm width, and is IP20 on the front — standard for enclosed panel installation. Phase failure detection is built in, so a lost phase on the line side will trip the breaker before the motor single-phases to failure.

Breaking capacity and coordination

Rated short-circuit breaking capacity is 100 kA at 240 V, 400 V, and 500 V AC, dropping to 8 kA at 690 V AC — that 100 kA figure means it can be used in high-fault panels without needing an upstream current-limiting fuse for most industrial installations up to 500 V. The auxiliary switch (transverse design) is included on this variant, so you get a status contact for PLC feedback or a holding circuit without adding a separate block. Screw-type terminals on the main circuit accept solid conductors 2x (0.5…1.5 mm²) and 2x (0.75…2.5 mm²), and stranded 2x (1…2.5 mm²) and 2x (2.5…6 mm²) — covers standard motor cable sizes up to 6 mm².

MPN
3RV1021-1DA15-ZW98