Siemens 3RV1021-1EA15-ZX95 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1021-1EA15-ZX95 SIRIUS Motor Protection Circuit B

MPN3RV1021-1EA15-ZX95

Siemens SIRIUS motor protection circuit breaker, 3RV1021-1EA15-ZX95, 4 A continuous rated current, Class 10 trip, 100 kA breaking capacity at 400 V AC, screw-type terminals, IP20 front.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV1021-1EA15-ZX95 — Identification
ParameterValue
SeriesSIRIUS
Product designationcircuit breaker
3RV1021-1EA15-ZX95 — Electrical
ParameterValue
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated impulse withstand voltage (Uimp)6 000 V
Number of poles3
Power loss (AC, hot)7.25 W
Power loss, per pole (AC, hot)2.4 W
3RV1021-1EA15-ZX95 — Protection & Tripping
ParameterValue
Overload release setting range2.8 ... 4 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)6 kA
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV1021-1EA15-ZX95 — Endurance & Switching
ParameterValue
Auxiliary CO (changeover) contacts0
3RV1021-1EA15-ZX95 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementfront side
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor range, AWG (main contacts)2x (14 ... 10)
3RV1021-1EA15-ZX95 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth96 mm
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
Mounting positionany
3RV1021-1EA15-ZX95 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Max. installation altitude2 000 m
3RV1021-1EA15-ZX95 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

Front IP20 means it's safe for finger contact inside an enclosure. Any mounting position is allowed, so panel layout is flexible. Main circuit terminals accept solid conductors 2x (0.5–1.5 mm²) and 2x (0.75–2.5 mm²), or stranded 2x (1–2.5 mm²) and 2x (2.5–6 mm²). Auxiliary and control circuits use screw-type terminals as well.

RoHS compliance date is 01.05.2012, so it meets the EU substance restrictions for current installations.

Frequently asked questions

Will 3RV1021-1EA15-ZX95 drop into a panel wired for 3RV1011-1AA15?

Both are SIRIUS motor protection breakers on the same 45 mm wide DIN-rail footprint, but the 3RV1011-1AA15 is a different current rating and trip class — verify the motor FLA and coordination study before swapping.

MPN
3RV1021-1EA15-ZX95