Siemens 3RV1021-1FA15-ZX95 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1021-1FA15-ZX95 SIRIUS Motor Circuit Breaker, 5 A

MPN3RV1021-1FA15-ZX95

Siemens SIRIUS 3RV1021-1FA15-ZX95 motor protection circuit breaker, 5 A continuous rated current, Class 10 trip, 100 kA breaking capacity at 400 V AC, screw terminals, 45 mm wide.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV1021-1FA15-ZX95 — Identification
ParameterValue
SeriesSIRIUS
Product designationcircuit breaker
3RV1021-1FA15-ZX95 — Electrical
ParameterValue
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated impulse withstand voltage (Uimp)6 000 V
Number of poles3
Power loss (AC, hot)7.25 W
Power loss, per pole (AC, hot)2.4 W
3RV1021-1FA15-ZX95 — Protection & Tripping
ParameterValue
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)6 kA
Phase-failure detectionYes
Ground-fault detectionNo
3RV1021-1FA15-ZX95 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
3RV1021-1FA15-ZX95 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementfront side
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
3RV1021-1FA15-ZX95 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth96 mm
Mounting positionany
3RV1021-1FA15-ZX95 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
3RV1021-1FA15-ZX95 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

Motor protection and trip behaviour

At 400 V the breaker is rated for a 1.5 kW motor; the same unit covers smaller loads down to the minimum setting of the adjustable thermal element.

Screw-type terminals on the main circuit accept 2x (0.5…1.5 mm²) solid or 2x (1…2.5 mm²) stranded — common for panel wiring with ferrule or direct termination. Auxiliary contacts are transverse design; the breaker ships with an auxiliary switch block fitted (0 built-in auxiliary contacts on the base unit, so the switch is an add-on module).

Environmental limits and mounting

Rated for -20 to +60 °C operating ambient, storage down to -50 °C, with shock resistance of 25 g / 11 ms — suitable for machine-mounted panels on presses or conveyors. Mountable in any position, with zero clearance required at the sides or rear — no derating needed for tight panel layouts.

Frequently asked questions

What is the continuous current rating of 3RV1021-1FA15-ZX95?

The continuous rated current is 5 A, with a Class 10 trip characteristic for motor overload protection.

MPN
3RV1021-1FA15-ZX95