Siemens 3RV1021-1GA38-1KT1 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1021-1GA38-1KT1 SIRIUS Motor Protection Circuit B

MPN3RV1021-1GA38-1KT1

Siemens SIRIUS motor protection circuit breaker, 3RV1021-1GA38-1KT1, 6.3 A continuous, CLASS 10 trip, 100 kA breaking at 400 V, screw/snap-on DIN rail.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3RV1021-1GA38-1KT1 — Identification
ParameterValue
SeriesSIRIUS
Product designationcircuit breaker

Electrical

3RV1021-1GA38-1KT1 — Electrical
ParameterValue
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated impulse withstand voltage (Uimp)6 000 V
Number of poles3
Power loss (AC, hot)7.25 W
Power loss, per pole (AC, hot)2.4 W

Protection & Tripping

3RV1021-1GA38-1KT1 — Protection & Tripping
ParameterValue
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)6 kA
Phase-failure detectionYes
Ground-fault detectionNo

Endurance & Switching

3RV1021-1GA38-1KT1 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h

Connections

3RV1021-1GA38-1KT1 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementfront side
Conductor cross-section, finely stranded with ferrule2x (0.25 ... 1.5 mm²)

Mechanical

3RV1021-1GA38-1KT1 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth96 mm
Mounting positionany

Environmental

3RV1021-1GA38-1KT1 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C

Specifications

3RV1021-1GA38-1KT1 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

Motor protection circuit breaker – 6.3 A, CLASS 10, 100 kA

The Siemens SIRIUS 3RV1021-1GA38-1KT1 is a motor protection circuit breaker rated for 6.3 A continuous current, with a CLASS 10 trip characteristic that clears overloads fast enough to protect standard induction motors during start-up (cites:,). Its breaking capacity hits 100 kA at 240 V, 400 V, and 500 V AC, dropping to 6 kA at 690 V AC — so on a 400 V line it interrupts fault currents up to 100 kA without cascading upstream (cites:,). Mounts on 35 mm DIN rail per EN 50022 via screw or snap-on; the 45 mm width and 96 mm depth fit standard panel layouts (cites:,).

Integration and environment

Rated IP20 on the front — suitable for enclosed panel use where no washdown or dust ingress is expected (cites:). Operates from -20 to +60 °C; stores and transports from -50 to +80 °C (cites:,). Shock-resistant to 25 g / 11 ms, and can be mounted in any position (cites:,).

Frequently asked questions

Will 3RV1021-1GA38-1KT1 drop into a panel specified around 3RV2021-1FA15 without rewiring?

Both mount on 35 mm DIN rail per EN 50022 and share the same 45 mm width, so the mechanical fit is identical — but verify the terminal ratings and auxiliary contact configuration because the 3RV1021-1GA38-1KT1 uses screw terminals for the main circuit and has a transverse auxiliary switch design (cites:,).

MPN
3RV1021-1GA38-1KT1