Siemens 3RV1021-1HA10-0FJ0-ZX95 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1021-1HA10-0FJ0-ZX95 SIRIUS Motor Protection Circ

MPN3RV1021-1HA10-0FJ0-ZX95

Siemens SIRIUS motor protection circuit breaker, 3RV1021-1HA10-0FJ0-ZX95, 8 A continuous rated current, CLASS 10 trip class, 100 kA breaking capacity at 400 V AC, screw-type terminals, 45 mm width.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV1021-1HA10-0FJ0-ZX95 — Identification
ParameterValue
SeriesSIRIUS
Product designationcircuit breaker
3RV1021-1HA10-0FJ0-ZX95 — Electrical
ParameterValue
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated impulse withstand voltage (Uimp)6 000 V
Number of poles3
Power loss (AC, hot)9.25 W
Power loss, per pole (AC, hot)3.1 W
3RV1021-1HA10-0FJ0-ZX95 — Protection & Tripping
ParameterValue
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)42 kA
Breaking capacity at 690 V (AC)6 kA
Phase-failure detectionYes
Ground-fault detectionNo
3RV1021-1HA10-0FJ0-ZX95 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
3RV1021-1HA10-0FJ0-ZX95 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementfront side
Conductor cross-section, finely stranded with ferrule2x (1 ... 2.5 mm²), 2x (2.5 ... 6 mm²)
3RV1021-1HA10-0FJ0-ZX95 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth96 mm
Mounting positionany
3RV1021-1HA10-0FJ0-ZX95 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
3RV1021-1HA10-0FJ0-ZX95 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

Breaking capacity and fault coordination

This breaker delivers 100 kA breaking capacity at 240 V AC and 400 V AC, 42 kA at 500 V AC, and 6 kA at 690 V AC.

Any mounting position is permitted.

Main current circuit terminals are screw-type, accepting 2× (1 to 2.5 mm²) solid or stranded, or 2× (2.5 to 6 mm²) — equivalent to 2× (14 to 10 AWG). The dual-conductor capacity per clamp is useful when looping through to a downstream contactor or overload relay without an additional terminal block. Backwards and side clearances are zero, so adjacent devices can mount flush.

Shock resistance is 25g for 11 ms, and surge voltage resistance is rated at 6 000 V. The mechanical endurance of the main contacts is 100 000 operations typical.

Protection features and auxiliary contacts

Ground fault detection is not included. The unit has no factory-fitted auxiliary contacts (0 auxiliary contacts), but an auxiliary switch option is available as an add-on accessory. Trip class is CLASS 10, and the maximum switching frequency at AC-3 duty is 15 operations per hour.

Frequently asked questions

Where can I buy 3RV1021-1HA10-0FJ0-ZX95?

This part is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.

What is the breaking capacity of this motor protection circuit breaker?

The breaking capacity is 100 kA at 240 V AC and 400 V AC, 42 kA at 500 V AC, and 6 kA at 690 V AC.

What wire sizes does the screw terminal accept?

The screw terminals accept 2× (1 to 2.5 mm²) solid or stranded, or 2× (2.5 to 6 mm²), equivalent to 2× (14 to 10 AWG).

Does this breaker include phase failure protection?

Yes, phase failure detection is built in. Ground fault detection is not included.