Siemens 3RV1021-1HA10-0FJ0-ZX95 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1021-1HA10-0FJ0-ZX95 SIRIUS Motor Protection Circ

MPN3RV1021-1HA10-0FJ0-ZX95

Siemens SIRIUS motor protection circuit breaker, 3RV1021-1HA10-0FJ0-ZX95, 8 A continuous rated current, CLASS 10 trip class, 100 kA breaking capacity at 400 V AC, screw-type terminals, 45 mm width.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3RV1021-1HA10-0FJ0-ZX95 — Identification
ParameterValue
SeriesSIRIUS
Product designationcircuit breaker

Electrical

3RV1021-1HA10-0FJ0-ZX95 — Electrical
ParameterValue
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated impulse withstand voltage (Uimp)6 000 V
Number of poles3
Power loss (AC, hot)9.25 W
Power loss, per pole (AC, hot)3.1 W

Protection & Tripping

3RV1021-1HA10-0FJ0-ZX95 — Protection & Tripping
ParameterValue
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)42 kA
Breaking capacity at 690 V (AC)6 kA
Phase-failure detectionYes
Ground-fault detectionNo

Endurance & Switching

3RV1021-1HA10-0FJ0-ZX95 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h

Connections

3RV1021-1HA10-0FJ0-ZX95 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementfront side
Conductor cross-section, finely stranded with ferrule2x (1 ... 2.5 mm²), 2x (2.5 ... 6 mm²)

Mechanical

3RV1021-1HA10-0FJ0-ZX95 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth96 mm
Mounting positionany

Environmental

3RV1021-1HA10-0FJ0-ZX95 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C

Specifications

3RV1021-1HA10-0FJ0-ZX95 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

The Siemens SIRIUS 3RV1021-1HA10-0FJ0-ZX95 is a motor protection circuit breaker rated for 8 A continuous current, sized for a 3 kW motor at 400 V AC. The CLASS 10 trip characteristic means it disconnects within 10 seconds at 7.2× the thermal setting — fast enough to protect a standard induction motor during a locked-rotor event without nuisance tripping on normal starting inrush.

Breaking capacity and fault coordination

This breaker delivers 100 kA breaking capacity at 240 V AC and 400 V AC, 42 kA at 500 V AC, and 6 kA at 690 V AC. At 400 V — the most common industrial motor supply — the 100 kA figure means it can safely interrupt a bolted fault up to that level without requiring an upstream current-limiting fuse for most installations. The 6 kA at 690 V still covers typical fault levels on 690 V systems, but verify the prospective short-circuit current at the point of installation.

Mounting and panel integration

Mounts via screw or snap-on onto 35 mm DIN rail per DIN EN 50022. The 45 mm width and 97 mm height fit a standard 45 mm modular device footprint; depth is 96 mm including the screw terminals. Any mounting position is permitted. The IP20 front protection means it's suitable for enclosed panel installation only — not for washdown or outdoor exposure without an additional enclosure.

Termination and wiring

Main current circuit terminals are screw-type, accepting 2× (1 to 2.5 mm²) solid or stranded, or 2× (2.5 to 6 mm²) — equivalent to 2× (14 to 10 AWG). The dual-conductor capacity per clamp is useful when looping through to a downstream contactor or overload relay without an additional terminal block. Backwards and side clearances are zero, so adjacent devices can mount flush.

Environmental and mechanical ratings

Operating temperature range is -20 to +60 °C; storage and transport range is -50 to +80 °C. Shock resistance is 25g for 11 ms, and surge voltage resistance is rated at 6 000 V. Maximum operating altitude is 2 000 m without derating. The mechanical endurance of the main contacts is 100 000 operations typical.

Protection features and auxiliary contacts

Phase failure detection is built in — the breaker trips on loss of any phase, preventing single-phasing damage to the motor. Ground fault detection is not included. The unit has no factory-fitted auxiliary contacts (0 auxiliary contacts), but an auxiliary switch option is available as an add-on accessory. Trip class is CLASS 10, and the maximum switching frequency at AC-3 duty is 15 operations per hour.

Frequently asked questions

Where can I buy 3RV1021-1HA10-0FJ0-ZX95?

This part is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.

What is the breaking capacity of this motor protection circuit breaker?

The breaking capacity is 100 kA at 240 V AC and 400 V AC, 42 kA at 500 V AC, and 6 kA at 690 V AC.

What wire sizes does the screw terminal accept?

The screw terminals accept 2× (1 to 2.5 mm²) solid or stranded, or 2× (2.5 to 6 mm²), equivalent to 2× (14 to 10 AWG).

Does this breaker include phase failure protection?

Yes, phase failure detection is built in. Ground fault detection is not included.

MPN
3RV1021-1HA10-0FJ0-ZX95