Skip to main content
Siemens 3RV1021-1HA10-ZW96 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1021-1HA10-ZW96 SIRIUS Motor Protection Circuit B

MPN3RV1021-1HA10-ZW96

Siemens SIRIUS 3RV1021-1HA10-ZW96 motor protection circuit breaker, 3-pole, 8 A rated continuous current, 3 kW at 400 V AC, Trip Class 10, screw-type terminals, 45 mm wide, IP20 front.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3RV1021-1HA10-ZW96 — Identification
ParameterValue
SeriesSIRIUS
Product designationcircuit breaker

Electrical

3RV1021-1HA10-ZW96 — Electrical
ParameterValue
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated impulse withstand voltage (Uimp)6 000 V
Number of poles3
Power loss (AC, hot)9.25 W
Power loss, per pole (AC, hot)3.1 W

Protection & Tripping

3RV1021-1HA10-ZW96 — Protection & Tripping
ParameterValue
Overload release setting range5.5 ... 8 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)42 kA
Breaking capacity at 690 V (AC)6 kA
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes

Endurance & Switching

3RV1021-1HA10-ZW96 — Endurance & Switching
ParameterValue
Auxiliary CO (changeover) contacts0

Connections

3RV1021-1HA10-ZW96 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementfront side
Conductor cross-section, finely stranded with ferrule2x (1 ... 2.5 mm²), 2x (2.5 ... 6 mm²)
Conductor range, AWG (main contacts)2x (14 ... 10)

Mechanical

3RV1021-1HA10-ZW96 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth96 mm
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
Mounting positionany

Environmental

3RV1021-1HA10-ZW96 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Max. installation altitude2 000 m

Specifications

3RV1021-1HA10-ZW96 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

What this part is and what it does

The Siemens 3RV1021-1HA10-ZW96 is a SIRIUS motor protection circuit breaker with screw-type terminals, designed to protect three-phase motors against overload, short-circuit, and phase failure. It carries a rated continuous current of 8 A and switches a 3 kW motor at 400 V AC. The Trip Class 10 characteristic means it will trip within 10 seconds at 7.2× the thermal setting — fast enough to protect standard induction motors during a locked-rotor event. Phase failure detection is built in, so a lost phase on the line side will trip the breaker before the motor single-phases to failure. The 45 mm wide body snaps onto a 35 mm DIN rail per DIN EN 50022, with screw and snap-on fastening. The IP20 front protection means it is safe for finger contact inside an enclosed panel but not for washdown environments. Mounting position is any, which helps when panel layout is tight.

Breaking capacity and selectivity

The interrupting ratings are 100 kA at 240 V AC, 100 kA at 400 V AC, 42 kA at 500 V AC, and 6 kA at 690 V AC. At 400 V — the most common industrial distribution voltage — the 100 kA SCCR means this breaker can be installed on a panel fed by a transformer of virtually any standard size without needing a current-limiting upstream device. At 690 V the 6 kA rating is lower but still covers most motor branch circuits in 690 V systems where the available fault current is typically below that level. Rated insulation voltage is 690 V, and surge voltage resistance is 6 000 V, which aligns with IEC 60947-2 overvoltage category III for fixed-installation equipment.

Terminal capacity and wiring

Screw-type terminals on both the main and auxiliary/control circuits. Each pole accepts 2× (1 … 2.5 mm²) solid or stranded, or 2× (2.5 … 6 mm²) — the larger cross-section is useful for looping through the line feed without a separate terminal block. Finely stranded wire with core end processing (ferrules) is also supported in the same ranges. AWG equivalents are 2× (14 … 10).

Environmental and compliance

Operating temperature range is -20 to +60 °C; storage and transport range is -50 to +80 °C. Shock resistance is 25 g for 11 ms. RoHS compliance date is 01.05.2012, meaning the part meets the EU RoHS substance restrictions from that date forward.

Frequently asked questions

Where can I buy 3RV1021-1HA10-ZW96 and how do I get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What is the closest functional second-source — 3RV1011-1HA10?

The 3RV1011-1HA10 is a physically smaller frame (S00 vs S0) with a lower maximum breaking capacity and different terminal layout. It will not drop into a panel wired for the 3RV1021-1HA10-ZW96 without re-drilling the mounting holes and re-terminating the conductors. The 3RV1021-1HA10-ZW96 is the correct replacement for any BOM that calls out the S0 frame size.

What is 3RV1021-1HA10-ZW96's listed depth?

The depth is 96 mm. Overall dimensions are 45 mm wide, 97 mm high, and 96 mm deep. The backwards projection from the DIN rail is 0 mm — the body sits flush against the rail.

What compliance documentation does this brand provide for 3RV1021-1HA10-ZW96?

The part is RoHS compliant per the substance prohibition date of 01.05.2012. It is designed to IEC 60947-2 and carries the SIRIUS brand documentation package including a CE declaration of conformity. UL and CSA listings are standard for the SIRIUS 3RV1 family, though specific file numbers are not listed in this entry.

MPN
3RV1021-1HA10-ZW96