Siemens SIRIUS motor-protective circuit breaker, 3RV1021-1JA10-ZW95, 10 A continuous rated current, Trip Class 10, 100 kA breaking capacity at 400 V AC, 3-pole, screw terminals, snap-on 35 mm DIN rail.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV1021-1JA10-ZW95 — Identification
ParameterValue
SeriesSIRIUS
Product designationcircuit breaker
3RV1021-1JA10-ZW95 — Electrical
ParameterValue
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated impulse withstand voltage (Uimp)6 000 V
Number of poles3
Power loss (AC, hot)9.25 W
Power loss, per pole (AC, hot)3.1 W
3RV1021-1JA10-ZW95 — Protection & Tripping
ParameterValue
Overload release setting range7 ... 10 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)42 kA
Breaking capacity at 690 V (AC)6 kA
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV1021-1JA10-ZW95 — Endurance & Switching
ParameterValue
Auxiliary CO (changeover) contacts0
3RV1021-1JA10-ZW95 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementfront side
Conductor cross-section, finely stranded with ferrule2x (1 ... 2.5 mm²), 2x (2.5 ... 6 mm²)
Conductor range, AWG (main contacts)2x (14 ... 10)
3RV1021-1JA10-ZW95 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth96 mm
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
Mounting positionany
3RV1021-1JA10-ZW95 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Max. installation altitude2 000 m
3RV1021-1JA10-ZW95 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

The Siemens SIRIUS 3RV1021-1JA10-ZW95 is a motor-protective circuit breaker rated for 10 A continuous current with Trip Class 10 thermal overload protection. At 45 mm wide, it fits a standard modular panel slot.

The 10 A continuous rating sets the motor FLA it can protect. Breaking capacity is 100 kA at 400 V AC and 240 V AC, 42 kA at 500 V AC, and 6 kA at 690 V AC. At 400 V, that 100 kA SCCR means it clears a bolted fault without the arc flash escalating — critical for panel coordination studies. The 4 kW motor rating at 400 V lines up with a typical 10 A motor full-load current on a 400 V line. IP20 on the front means fingers won't reach live parts inside the panel. The -50 to +80 °C storage range and -20 to +60 °C operating range cover unheated warehouses and hot machine cabinets. Shock rated at 25g / 11 ms — it stays calibrated on a vibrating conveyor or pump skid.

Zero clearance needed at the sides or back — 0 mm backwards and 0 mm at the side — so you can pack it tight in a crowded panel. Dimensions: 45 mm wide, 97 mm tall, 96 mm deep. Screw terminals accept 1x to 2x (1... 2.5 mm²) solid or stranded, and 2x (2.5... 6 mm²) solid or stranded on the main circuit. Fine-stranded with ferrule: same ranges. AWG equivalents: 2x (14... 10). Auxiliary and control circuits also use screw terminals. An auxiliary switch can be added — the product extension for that is supported.

RoHS compliant per the substance prohibition date of 01.05.2012. The rated impulse withstand voltage is 6 000 V, and operating frequency for AC-3 duty is max 15 operations per hour.

Frequently asked questions

Where can I buy 3RV1021-1JA10-ZW95?

We source and quote this part to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is the breaking capacity of 3RV1021-1JA10-ZW95?

100 kA at 240 V AC and 400 V AC, 42 kA at 500 V AC, and 6 kA at 690 V AC. That 100 kA at 400 V is what matters for most industrial motor panels.

Does 3RV1021-1JA10-ZW95 have phase failure detection?

Yes, phase failure detection is built in. A lost phase will trip the breaker, protecting the motor from single-phasing.

What wire sizes does the 3RV1021-1JA10-ZW95 accept?

Screw terminals accept 1x to 2x (1... 2.5 mm²) and 2x (2.5... 6 mm²) solid or stranded, or 2x (14... 10) AWG. Fine-stranded with ferrule uses the same ranges.