Siemens 3RV1021-1JA10-ZW97 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1021-1JA10-ZW97 SIRIUS Motor Protection Circuit B

MPN3RV1021-1JA10-ZW97

Siemens SIRIUS motor protection circuit breaker, 3RV1021-1JA10-ZW97, 10 A continuous, 4 kW at 400 V, CLASS 10 trip, screw terminals, snap-on DIN rail mount.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3RV1021-1JA10-ZW97 — Identification
ParameterValue
SeriesSIRIUS
Product designationcircuit breaker

Electrical

3RV1021-1JA10-ZW97 — Electrical
ParameterValue
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated impulse withstand voltage (Uimp)6 000 V
Number of poles3
Power loss (AC, hot)9.25 W
Power loss, per pole (AC, hot)3.1 W

Protection & Tripping

3RV1021-1JA10-ZW97 — Protection & Tripping
ParameterValue
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)42 kA
Breaking capacity at 690 V (AC)6 kA
Phase-failure detectionYes
Ground-fault detectionNo

Endurance & Switching

3RV1021-1JA10-ZW97 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h

Connections

3RV1021-1JA10-ZW97 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementfront side
Conductor cross-section, finely stranded with ferrule2x (1 ... 2.5 mm²), 2x (2.5 ... 6 mm²)

Mechanical

3RV1021-1JA10-ZW97 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth96 mm
Mounting positionany

Environmental

3RV1021-1JA10-ZW97 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C

Specifications

3RV1021-1JA10-ZW97 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

SIRIUS 3RV1021-1JA10-ZW97 — Motor Protection Circuit Breaker, 10 A, CLASS 10

The Siemens 3RV1021-1JA10-ZW97 is a SIRIUS motor protection circuit breaker designed for motor protection, rated at 10 A continuous current and 4 kW at 400 V AC-3 duty. Its CLASS 10 trip characteristic means it disconnects within 10 seconds at 7.2× rated current — fast enough to protect standard induction motors during a locked-rotor event without nuisance tripping on normal starts. Breaking capacity is 100 kA at 240 V and 400 V AC, dropping to 42 kA at 500 V and 6 kA at 690 V. That 100 kA at 400 V is the figure that governs most industrial panel SCCR calculations — it lets this breaker sit upstream of smaller branch devices without requiring a current-limiting fuse ahead of it. Phase failure detection is built in. If one phase drops out, the breaker trips — preventing single-phasing damage to the motor. Ground fault detection is not included, so for applications requiring GF protection, an external module or separate GF relay is needed.

Mounting and Integration

Mounts via screw or snap-on onto 35 mm DIN rail per EN 50022. The 45 mm width and 96 mm depth fit standard panel layouts. Any mounting position is allowed, which simplifies layout in tight enclosures. Front face carries IP20 protection — touch-safe for the operator side, but not sealed against dust ingress into the panel. Main circuit connections are screw-type terminals. Solid and stranded conductors: 2x (1 … 2.5 mm²) or 2x (2.5 … 6 mm²) per terminal. AWG equivalents for main contacts: 2x (14 … 10). No auxiliary contacts are factory-fitted, but an auxiliary switch can be added.

Environmental and Durability

Operating temperature range is -20 to +60 °C; storage and transport range is -50 to +80 °C. Shock resistance rated at 25 g for 11 ms. Mechanical endurance of the main contacts is typically 100,000 operations. Power dissipation at rated current in hot operating state is 9.25 W total, 3.1 W per pole.

Frequently asked questions

What is the breaking capacity of this circuit breaker at 400 V?

The breaking capacity at 400 V AC is 100 kA. This high interrupting rating allows it to be used as a main branch protector without requiring upstream current-limiting fuses in most industrial panels.

What does CLASS 10 trip mean for motor protection?

CLASS 10 means the breaker will trip within 10 seconds at 7.2 times the rated current. This is fast enough to protect standard induction motors during a locked-rotor condition while allowing normal starting inrush without nuisance trips.

Does this breaker include phase failure protection?

Yes, phase failure detection is built in. If one phase is lost, the breaker trips to prevent single-phasing damage to the motor.

How do I get pricing and availability for 3RV1021-1JA10-ZW97?

This part is sourced to order against an RFQ through independent distribution. Submit a request for quote (RFQ) to receive current pricing and confirmed availability.