Siemens 3RV1021-1JA15-ZW95 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1021-1JA15-ZW95 SIRIUS Motor Protection Circuit B

MPN3RV1021-1JA15-ZW95

Siemens SIRIUS motor protection circuit breaker, 3RV1021-1JA15-ZW95, 10 A continuous, CLASS 10 trip, 100 kA breaking capacity at 400 V AC, 4 kW motor rating at 400 V, screw terminals, snap-on DIN rail.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3RV1021-1JA15-ZW95 — Identification
ParameterValue
SeriesSIRIUS
Product designationcircuit breaker

Electrical

3RV1021-1JA15-ZW95 — Electrical
ParameterValue
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated impulse withstand voltage (Uimp)6 000 V
Number of poles3
Power loss (AC, hot)9.25 W
Power loss, per pole (AC, hot)3.1 W

Protection & Tripping

3RV1021-1JA15-ZW95 — Protection & Tripping
ParameterValue
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)42 kA
Breaking capacity at 690 V (AC)6 kA
Phase-failure detectionYes
Ground-fault detectionNo

Endurance & Switching

3RV1021-1JA15-ZW95 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h

Connections

3RV1021-1JA15-ZW95 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementfront side
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)

Mechanical

3RV1021-1JA15-ZW95 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth96 mm
Mounting positionany

Environmental

3RV1021-1JA15-ZW95 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C

Specifications

3RV1021-1JA15-ZW95 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

SIRIUS motor protection circuit breaker, 10 A, CLASS 10

The Siemens 3RV1021-1JA15-ZW95 is a SIRIUS motor protection circuit breaker designed for motor protection, rated at 10 A continuous current with a CLASS 10 trip characteristic, meaning it will trip within 10 seconds at 7.2× rated current — fast enough to protect standard induction motors during locked-rotor conditions. It mounts via screw or snap-on onto 35 mm DIN rail per DIN EN 50022, fitting a 45 mm wide footprint with 96 mm depth and 97 mm height, and accepts screw-type terminals for the main circuit. The breaker includes an auxiliary switch (transverse design) and provides phase failure detection, but no ground fault detection.

Breaking capacity and motor power

Breaking capacity reaches 100 kA at 240 V AC and 400 V AC, 42 kA at 500 V AC, and 6 kA at 690 V AC — sufficient for high-fault industrial panels. Motor power rating is 4 kW at 400 V AC-3, with a maximum switching frequency of 15 operations per hour at AC-3 duty. Rated insulation voltage is 690 V; the auxiliary contacts switch 1 A at 24 V, 0.5 A at 230 V, and 0.15 A at 60 V.

Environmental and mechanical ratings

Operates from -20 °C to +60 °C, stores and transports from -50 °C to +80 °C, and is rated for altitudes up to 2,000 m. Shock resistance is 25g for 11 ms; mounting position is any orientation, with zero clearance required at the back or sides. Front face is IP20; mechanical endurance of the main contacts is 100,000 operations typical. Power loss at rated current in hot operating state is 9.25 W.

Terminal capacity

Screw terminals accept solid conductors: 2×(0.5…1.5 mm²) and 2×(0.75…2.5 mm²); stranded: 2×(1…2.5 mm²) and 2×(2.5…6 mm²).

Frequently asked questions

Does 3RV1021-1JA15-ZW95 include an auxiliary switch?

Yes, it includes an auxiliary switch (transverse design).

MPN
3RV1021-1JA15-ZW95