Siemens 3RV1021-1JA15-ZW96 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1021-1JA15-ZW96 SIRIUS Motor Protection Circuit B

MPN3RV1021-1JA15-ZW96

Siemens SIRIUS motor protection circuit breaker, 3RV1021-1JA15-ZW96, 10 A continuous rated current, CLASS 10 trip class, 100 kA breaking capacity at 400 V AC, screw-type terminals, 45 x 97 x 96 mm.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3RV1021-1JA15-ZW96 — Identification
ParameterValue
SeriesSIRIUS
Product designationcircuit breaker

Electrical

3RV1021-1JA15-ZW96 — Electrical
ParameterValue
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated impulse withstand voltage (Uimp)6 000 V
Number of poles3
Power loss (AC, hot)9.25 W
Power loss, per pole (AC, hot)3.1 W

Protection & Tripping

3RV1021-1JA15-ZW96 — Protection & Tripping
ParameterValue
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)42 kA
Breaking capacity at 690 V (AC)6 kA
Phase-failure detectionYes
Ground-fault detectionNo

Endurance & Switching

3RV1021-1JA15-ZW96 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h

Connections

3RV1021-1JA15-ZW96 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementfront side
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)

Mechanical

3RV1021-1JA15-ZW96 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth96 mm
Mounting positionany

Environmental

3RV1021-1JA15-ZW96 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C

Specifications

3RV1021-1JA15-ZW96 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

Motor protection circuit breaker for DIN-rail panels

The Siemens 3RV1021-1JA15-ZW96 is a SIRIUS motor protection circuit breaker designed for screw and snap-on mounting onto 35 mm standard mounting rail per DIN EN 50022, making it a direct fit for any IEC-style control panel. It carries a continuous current rated value of 10 A and is rated for 4 kW at 400 V, which covers a typical small motor on a pump or conveyor. The CLASS 10 trip class means it will trip within 10 seconds at 7.2× rated current, matching the thermal characteristic of standard induction motors during startup — important for avoiding nuisance trips on high-inertia loads.

Breaking capacity and fault clearing

This breaker delivers 100 kA breaking capacity at both 240 V and 400 V AC, dropping to 42 kA at 500 V and 6 kA at 690 V. At 400 V — the most common industrial distribution voltage — the 100 kA figure means it can safely interrupt a bolted fault on a high-capacity transformer secondary without needing an upstream current-limiting fuse. The phase failure detection built into the SIRIUS design adds a layer of protection for three-phase motors running on supply legs that may drop one phase.

Terminal capacity and wiring

Screw-type terminals on the main current circuit accept solid conductors: 2x (0.5 … 1.5 mm²) and 2x (0.75 … 2.5 mm²). Stranded conductors: 2x (1 … 2.5 mm²) and 2x (2.5 … 6 mm²). The auxiliary switch is transverse design with its own terminal set. The IP20 rating on the front means the breaker is touch-safe for panel interiors but not suitable for washdown environments. Mounting position is any, which simplifies layout in tight enclosures.

Environmental and mechanical limits

Operating temperature range is -20 to +60 °C; storage and transport range is -50 to +80 °C. Shock resistance is rated at 25g / 11 ms, which covers most industrial vibration environments. Maximum operating altitude is 2 000 m without derating. The mechanical endurance of the main contacts is typically 100 000 operations, and the maximum switching frequency in AC-3 duty is 15 operations per hour.

Frequently asked questions

What is the breaking capacity of 3RV1021-1JA15-ZW96 at 400 V?

100 kA at 400 V AC, which is the standard industrial distribution voltage for most panels.

What trip class does this motor protection circuit breaker have?

CLASS 10, meaning it trips within 10 seconds at 7.2× rated current, matching standard induction motor startup characteristics.

What wire sizes does the screw terminal accept?

Solid: 2x (0.5 … 1.5 mm²) and 2x (0.75 … 2.5 mm²). Stranded: 2x (1 … 2.5 mm²) and 2x (2.5 … 6 mm²).

Where can I buy 3RV1021-1JA15-ZW96 and get current pricing?

This part is sourced and quoted to order through independent distribution. Availability and current pricing are confirmed at quote time against an RFQ.