Siemens SIRIUS 3RV1021-1KA10-ZW96 motor protection circuit breaker, 3-pole, 12.5 A rated continuous current, 5.5 kW at 400 V AC-3, 100 kA breaking capacity at 400 V, Class 10 trip, screw terminals, IP20 front, DIN rail mount.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3RV1021-1KA10-ZW96 — Identification
ParameterValue
SeriesSIRIUS
Product designationcircuit breaker

Electrical

3RV1021-1KA10-ZW96 — Electrical
ParameterValue
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated impulse withstand voltage (Uimp)6 000 V
Number of poles3
Power loss (AC, hot)9.25 W
Power loss, per pole (AC, hot)3.1 W

Protection & Tripping

3RV1021-1KA10-ZW96 — Protection & Tripping
ParameterValue
Overload release setting range9 ... 12.5 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)42 kA
Breaking capacity at 690 V (AC)6 kA
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes

Endurance & Switching

3RV1021-1KA10-ZW96 — Endurance & Switching
ParameterValue
Auxiliary CO (changeover) contacts0

Connections

3RV1021-1KA10-ZW96 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementfront side
Conductor cross-section, finely stranded with ferrule2x (1 ... 2.5 mm²), 2x (2.5 ... 6 mm²)
Conductor range, AWG (main contacts)2x (14 ... 10)

Mechanical

3RV1021-1KA10-ZW96 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth96 mm
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
Mounting positionany

Environmental

3RV1021-1KA10-ZW96 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Max. installation altitude2 000 m

Specifications

3RV1021-1KA10-ZW96 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

SIRIUS 3RV1021-1KA10-ZW96 — Motor Protection Circuit Breaker, 12.5 A

The Siemens 3RV1021-1KA10-ZW96 is a SIRIUS motor protection circuit breaker rated for 12.5 A continuous current, switching 5.5 kW at 400 V in AC-3 duty. It's a 3-pole device with screw-type terminals for main and auxiliary circuits, designed for protecting motor feeders against overload and short-circuit. The 12.5 A rating sets the thermal overload threshold. The breaker trips on overload per its Class 10 characteristic. Breaking capacity is 100 kA at 400 V AC, dropping to 42 kA at 500 V and 6 kA at 690 V. At 240 V it's also 100 kA. That 100 kA at 400 V means this breaker can safely interrupt a fault current up to that level without welding contacts or rupturing — critical for high-fault panels near large transformers.

Mounting and Integration

Mounts via screw or snap-on onto 35 mm DIN rail per DIN EN 50022. The 45 mm width (3-module) fits standard enclosure rail. Any mounting position allowed, with 0 mm clearance needed at the sides or rear — tight panel layouts are fine. Terminals accept 2x (1 to 2.5 mm²) solid or stranded, or 2x (2.5 to 6 mm²) — covers most motor feeder cables up to 6 mm². AWG equivalent 14 to 10. Screw-type terminals on main and aux circuits; no special tooling needed. IP20 protection on the front face — suitable for enclosure-mounted breakers where the front is operator-accessible but the busbars are behind a panel door. Not for washdown environments.

Environmental and Compliance

Operating temperature range -20 to +60 °C, storage and transport -50 to +80 °C. Shock rated 25g for 11 ms — survives typical shipping and panel vibration. RoHS compliance date marked 01.05.2012 — the part meets the EU RoHS substance restrictions as of that date. Surge voltage resistance rated 6000 V, which covers the impulse withstand for standard 400 V industrial installations. Phase failure detection is built in — the breaker will trip if one phase drops out, protecting the motor from single-phasing. No ground fault detection on this variant.

Frequently asked questions

Does 3RV1021-1KA10-ZW96 include phase failure protection?

Yes, phase failure detection is built in. Ground fault detection is not included on this variant.

What wire sizes does 3RV1021-1KA10-ZW96 accept?

Screw terminals accept 2x (1 to 2.5 mm²) or 2x (2.5 to 6 mm²) solid or stranded, AWG 14 to 10.