Siemens 3RV1021-1KA10-ZX95 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1021-1KA10-ZX95 SIRIUS Motor Protection Circuit B

MPN3RV1021-1KA10-ZX95

Siemens SIRIUS, motor protection circuit breaker, 3RV1021-1KA10-ZX95, 12.5 A continuous, CLASS 10 trip, 100 kA breaking capacity at 400 V AC, screw terminals, 45 mm width.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV1021-1KA10-ZX95 — Identification
ParameterValue
SeriesSIRIUS
Product designationcircuit breaker
3RV1021-1KA10-ZX95 — Electrical
ParameterValue
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated impulse withstand voltage (Uimp)6 000 V
Number of poles3
Power loss (AC, hot)9.25 W
Power loss, per pole (AC, hot)3.1 W
3RV1021-1KA10-ZX95 — Protection & Tripping
ParameterValue
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)42 kA
Breaking capacity at 690 V (AC)6 kA
Phase-failure detectionYes
Ground-fault detectionNo
3RV1021-1KA10-ZX95 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
3RV1021-1KA10-ZX95 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementfront side
Conductor cross-section, finely stranded with ferrule2x (1 ... 2.5 mm²), 2x (2.5 ... 6 mm²)
3RV1021-1KA10-ZX95 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth96 mm
Mounting positionany
3RV1021-1KA10-ZX95 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
3RV1021-1KA10-ZX95 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

Motor protection circuit breaker, 12.5 A, CLASS 10

Its 12.5 A continuous current rating and CLASS 10 trip characteristic mean it clears a stalled-rotor condition fast enough to protect standard IEC induction motors before winding temperature exceeds the insulation class — that is the core job this part is built for. Rated breaking capacity reaches 100 kA at 400 V AC, dropping to 42 kA at 500 V and 6 kA at 690 V. That means if one phase drops on a three-phase motor, the breaker trips before single-phasing cooks the winding — a standard requirement for motor protection under IEC 60947-4-1.

Any mounting position is allowed, which helps when the enclosure is tight on vertical space. Screw terminals on the main circuit accept solid or stranded conductors: 2x (1 … 2.5 mm²) and 2x (2.5 … 6 mm²), or AWG 14–10.

Frequently asked questions

What is the breaking capacity of this circuit breaker at 400 V?

100 kA at 400 V AC. At 500 V it drops to 42 kA, and at 690 V to 6 kA.

Does this breaker include phase failure protection?

Yes, phase failure detection is built in, protecting the motor against single-phasing.

What is the trip class and what does it mean?

CLASS 10 — the breaker trips within 10 seconds at a locked-rotor current, matching the thermal withstand of standard IEC induction motors.

What is the power dissipation of this device?

9.25 W total in hot operating state at AC, or 3.1 W per pole. Useful for enclosure heat calculations.

How do I get pricing and availability for the 3RV1021-1KA10-ZX95?

This part is sourced to order against an RFQ through independent distribution. Submit a request for current pricing and availability — confirmed at quote time.