Skip to main content
Siemens 3RV1021-4AA10-ZW97 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1021-4AA10-ZW97 SIRIUS Motor Protection Circuit B

MPN3RV1021-4AA10-ZW97

Siemens SIRIUS motor protection circuit breaker, 3RV1021-4AA10-ZW97, 16 A continuous, 7.5 kW at 400 V AC, Class 10 trip, screw terminals, 45 mm wide.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV1021-4AA10-ZW97 — Identification
ParameterValue
SeriesSIRIUS
Product designationcircuit breaker
3RV1021-4AA10-ZW97 — Electrical
ParameterValue
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated impulse withstand voltage (Uimp)6 000 V
Number of poles3
Power loss (AC, hot)9.25 W
Power loss, per pole (AC, hot)3.1 W
3RV1021-4AA10-ZW97 — Protection & Tripping
ParameterValue
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)50 kA
Breaking capacity at 500 V (AC)10 kA
Breaking capacity at 690 V (AC)4 kA
Phase-failure detectionYes
Ground-fault detectionNo
3RV1021-4AA10-ZW97 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
3RV1021-4AA10-ZW97 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementfront side
Conductor cross-section, finely stranded with ferrule2x (1 ... 2.5 mm²), 2x (2.5 ... 6 mm²)
3RV1021-4AA10-ZW97 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth96 mm
Mounting positionany
3RV1021-4AA10-ZW97 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
3RV1021-4AA10-ZW97 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

The Siemens SIRIUS 3RV1021-4AA10-ZW97 is a motor protection circuit breaker designed for motor protection, rated 16 A continuous current and 7.5 kW at 400 V AC in AC-3 duty.

Breaking capacity reaches 100 kA at 240 V AC, 50 kA at 400 V AC, 10 kA at 500 V AC, and 4 kA at 690 V AC.

Width is 45 mm, depth 96 mm, height 97 mm. Any mounting position allowed. No side clearance needed — 0 mm backwards and at the side — so it packs tight on the rail without derating. Front face is IP20, safe for finger-probe access inside an enclosed panel.

Terminals and wiring

Main circuit uses screw-type terminals. Accepts 2x (1 … 2.5 mm²) solid or stranded, and 2x (2.5 … 6 mm²) solid or stranded. AWG equivalent is 2x (14 … 10) for the main contacts. Finely stranded with core-end processing also accepted in the same ranges. That covers most panel-building wire sizes up to 6 mm² without needing ferrules for fine-stranded wire.

Shock resistance rated at 25 g / 11 ms, which covers most industrial vibration environments. Mechanical endurance of the main contacts is 100,000 operations typical. No ground fault detection on this variant.

Frequently asked questions

Where can I buy 3RV1021-4AA10-ZW97 and what is the lead time?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is the breaking capacity of 3RV1021-4AA10-ZW97 at 400 V?

50 kA at 400 V AC — that's the figure that governs most industrial panel SCCR calculations.

Does 3RV1021-4AA10-ZW97 include phase failure protection?

Yes, phase failure detection is built in — it trips on loss of a phase to prevent single-phasing damage on three-phase motors.

What is the trip class of this breaker?

Class 10 — it clears a stalled-rotor overload fast enough to protect standard induction motors without nuisance tripping on normal start-up inrush.

MPN
3RV1021-4AA10-ZW97