Skip to main content
Siemens 3RV1021-4BA15 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1021-4BA15 SIRIUS Motor Circuit Breaker, 20 A, CL

MPN3RV1021-4BA15

Siemens SIRIUS 3RV1021-4BA15 motor-protective circuit breaker, 20 A continuous rated current, CLASS 10 trip class, 50 kA breaking capacity at 400 V AC, screw terminals, for 35 mm DIN rail.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3RV1021-4BA15 — Identification
ParameterValue
SeriesSIRIUS
Product designationcircuit breaker
3RV1021-4BA15 — Electrical
ParameterValue
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated impulse withstand voltage (Uimp)6 000 V
Number of poles3
Power loss (AC, hot)10.5 W
Power loss, per pole (AC, hot)3.5 W
3RV1021-4BA15 — Protection & Tripping
ParameterValue
Overload release setting range14 ... 20 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)50 kA
Breaking capacity at 500 V (AC)10 kA
Breaking capacity at 690 V (AC)4 kA
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV1021-4BA15 — Endurance & Switching
ParameterValue
Auxiliary CO (changeover) contacts0
3RV1021-4BA15 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementfront side
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
3RV1021-4BA15 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth96 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 50022
Mounting positionany
3RV1021-4BA15 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Max. installation altitude2 000 m
3RV1021-4BA15 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

SIRIUS 3RV1021-4BA15 — motor-protective circuit breaker, 20 A, CLASS 10

The Siemens SIRIUS 3RV1021-4BA15 is a motor-protective circuit breaker rated for 20 A continuous current with a CLASS 10 trip characteristic, meaning it protects standard induction motors against overload and short-circuit by tripping within 10 seconds at 7.2× rated current — fast enough for most pump, fan, and conveyor applications without nuisance tripping on startup inrush. Rated breaking capacity reaches 100 kA at 240 V AC, 50 kA at 400 V AC, 10 kA at 500 V AC, and 4 kA at 690 V AC — sufficient for high-fault panels downstream of a distribution transformer.

Occupies 45 mm width on the rail — standard for this SIRIUS frame size. Depth is 96 mm, height 97 mm. Front protection class IP20 — safe for finger contact in an enclosed panel. Solid wire accepts 2× (0.5…1.5 mm²) and 2× (0.75…2.5 mm²); stranded accepts 2× (1…2.5 mm²) and 2× (2.5…6 mm²).

Auxiliary switch and control ratings

The design accepts an auxiliary switch module (transverse type) — product extension is supported, so you can add a signal contact for remote status indication without replacing the breaker. Auxiliary contact ratings: 1 A at 24 V, 0.5 A at 230 V, 0.15 A at 60 V — sufficient for PLC digital inputs or indicator lamps.

Shock rated at 25 g / 11 ms. Mountable in any position. Surge voltage resistance rated at 6 000 V. RoHS compliance date 05/01/2012 — substance prohibited per EU directive. No ground fault detection built in; that requires an add-on module.

Frequently asked questions

What is the breaking capacity of 3RV1021-4BA15 at 400 V?

50 kA at 400 V AC. At 240 V it is 100 kA, at 500 V it drops to 10 kA, and at 690 V to 4 kA.

What motor power does 3RV1021-4BA15 protect at 400 V?

Rated for 7.5 kW at 400 V AC-3 duty — typical for a 10 HP induction motor in a 400 V three-phase system.

Where can I buy 3RV1021-4BA15?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing confirmed at quote time.

Does 3RV1021-4BA15 include phase failure protection?

Yes, phase failure detection is built in — the breaker will trip on a lost phase to prevent single-phasing motor damage.

MPN