Siemens 3RV1021-4BA15-ZW97 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1021-4BA15-ZW97 SIRIUS Motor Protection Circuit B

MPN3RV1021-4BA15-ZW97

Siemens SIRIUS motor protection circuit breaker, 3RV1021-4BA15-ZW97, 20 A continuous, CLASS 10 trip, 7.5 kW at 400 V, screw terminals, IP20 front.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV1021-4BA15-ZW97 — Identification
ParameterValue
SeriesSIRIUS
Product designationcircuit breaker
3RV1021-4BA15-ZW97 — Electrical
ParameterValue
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated impulse withstand voltage (Uimp)6 000 V
Number of poles3
Power loss (AC, hot)10.5 W
Power loss, per pole (AC, hot)3.5 W
3RV1021-4BA15-ZW97 — Protection & Tripping
ParameterValue
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)50 kA
Breaking capacity at 500 V (AC)10 kA
Breaking capacity at 690 V (AC)4 kA
Phase-failure detectionYes
Ground-fault detectionNo
3RV1021-4BA15-ZW97 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
3RV1021-4BA15-ZW97 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementfront side
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
3RV1021-4BA15-ZW97 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth96 mm
Mounting positionany
3RV1021-4BA15-ZW97 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
3RV1021-4BA15-ZW97 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

Motor protection circuit breaker for the panel line

The Siemens SIRIUS 3RV1021-4BA15-ZW97 is a motor protection circuit breaker rated for 20 A continuous current, sized for a 7.5 kW motor at 400 V AC. Trip class is CLASS 10.

Shock rated at 25g for 11 ms — survives transport and normal industrial vibration without nuisance trips.

Terminal capacity and auxiliary contacts

Main circuit terminals accept solid conductors from 0.5 to 1.5 mm² (two per clamp) and stranded from 1 to 2.5 mm² (two per clamp). The auxiliary switch is transverse design, rated 1 A at 24 V, 0.5 A at 230 V, 0.15 A at 60 V — enough for a PLC input or contactor coil feedback, but not for direct motor switching. No ground fault detection on this unit; phase failure detection is present. Mechanical endurance of the main contacts is 100,000 operations typical.

Frequently asked questions

What is the closest functional alternative to 3RV1021-4BA15-ZW97?

The 3RV6011-0CA10 is a functionally similar SIRIUS motor protection breaker but check the continuous current rating and trip class against your motor FLA — the 3RV1021-4BA15-ZW97 is rated 20 A, CLASS 10, with phase failure detection. Panel footprint and terminal style may differ; verify dimensions before drop-in substitution.