Siemens 3RV1021-4CA10-0FJ0-ZX95 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1021-4CA10-0FJ0-ZX95 SIRIUS Motor Protection Circ

MPN3RV1021-4CA10-0FJ0-ZX95

Siemens SIRIUS motor protection circuit breaker, 3RV1021-4CA10-0FJ0-ZX95, 22 A continuous rated current, CLASS 10 trip class, 11 kW at 400 V, screw-type terminals, snap-on DIN rail mounting.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3RV1021-4CA10-0FJ0-ZX95 — Identification
ParameterValue
SeriesSIRIUS
Product designationcircuit breaker
3RV1021-4CA10-0FJ0-ZX95 — Electrical
ParameterValue
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated impulse withstand voltage (Uimp)6 000 V
Number of poles3
Power loss (AC, hot)10.5 W
Power loss, per pole (AC, hot)3.5 W
3RV1021-4CA10-0FJ0-ZX95 — Protection & Tripping
ParameterValue
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)50 kA
Breaking capacity at 500 V (AC)10 kA
Breaking capacity at 690 V (AC)4 kA
Phase-failure detectionYes
Ground-fault detectionNo
3RV1021-4CA10-0FJ0-ZX95 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
3RV1021-4CA10-0FJ0-ZX95 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementfront side
Conductor cross-section, finely stranded with ferrule2x (1 ... 2.5 mm²), 2x (2.5 ... 6 mm²)
3RV1021-4CA10-0FJ0-ZX95 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth96 mm
Mounting positionany
3RV1021-4CA10-0FJ0-ZX95 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
3RV1021-4CA10-0FJ0-ZX95 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

Motor Protection Circuit Breaker — SIRIUS 3RV1021-4CA10-0FJ0-ZX95

No ground fault detection on this variant — that's a separate function.

Breaking Capacity and Voltage Ratings

Breaking capacity at 240 V AC is 100 kA, at 400 V AC it's 50 kA, at 500 V AC it's 10 kA, and at 690 V AC it's 4 kA. Surge voltage resistance rated value is 6 000 V, which covers the impulse withstand requirements for industrial environments per IEC 60947-2.

Width is 45 mm, height 97 mm, depth 96 mm — a standard 45 mm module that fits alongside contactors and overloads in a motor starter row. Terminals are screw-type for the main current circuit. Solid and stranded conductors: 2x (1... 2.5 mm²) and 2x (2.5... 6 mm²). AWG equivalents for main contacts: 2x (14... 10). Finely stranded with core end processing also accepts 2x (1... 2.5 mm²) and 2x (2.5... 6 mm²). That covers the common panel wire sizes for a 22 A circuit. Shock resistance is 25g / 11 ms.

Power dissipation at AC in hot operating state is 10.5 W total, 3.5 W per pole. Mechanical endurance of the main contacts is 100 000 operations typical. Maximum switching rate at AC-3 is 15 cycles per hour.

Frequently asked questions

How do I get current pricing and availability for 3RV1021-4CA10-0FJ0-ZX95?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is 3RV1021-4CA10-0FJ0-ZX95's listed depth?

The depth is 96 mm.

What wire sizes does the 3RV1021-4CA10-0FJ0-ZX95 accept?

Solid and stranded conductors: 2x (1... 2.5 mm²) and 2x (2.5... 6 mm²). AWG equivalents for main contacts: 2x (14... 10). Finely stranded with core end processing also accepts 2x (1... 2.5 mm²) and 2x (2.5... 6 mm²).

What is the breaking capacity of 3RV1021-4CA10-0FJ0-ZX95 at 400 V?

50 kA at 400 V AC.