Siemens SIRIUS motor protection circuit breaker, 3RV1021-4CA10-ZW95, 22 A continuous, 11 kW at 400 V AC-3, CLASS 10 trip, screw terminals, snap-on DIN rail.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV1021-4CA10-ZW95 — Identification
ParameterValue
SeriesSIRIUS
Product designationcircuit breaker
3RV1021-4CA10-ZW95 — Electrical
ParameterValue
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated impulse withstand voltage (Uimp)6 000 V
Number of poles3
Power loss (AC, hot)10.5 W
Power loss, per pole (AC, hot)3.5 W
3RV1021-4CA10-ZW95 — Protection & Tripping
ParameterValue
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)50 kA
Breaking capacity at 500 V (AC)10 kA
Breaking capacity at 690 V (AC)4 kA
Phase-failure detectionYes
Ground-fault detectionNo
3RV1021-4CA10-ZW95 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
3RV1021-4CA10-ZW95 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementfront side
Conductor cross-section, finely stranded with ferrule2x (1 ... 2.5 mm²), 2x (2.5 ... 6 mm²)
3RV1021-4CA10-ZW95 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth96 mm
Mounting positionany
3RV1021-4CA10-ZW95 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
3RV1021-4CA10-ZW95 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

The Siemens SIRIUS 3RV1021-4CA10-ZW95 is a motor protection circuit breaker rated for 22 A continuous current and 11 kW at 400 V in AC-3 duty — that's the motor-switching rating, so it directly covers a 22 A full-load motor on a 400 V line.

Short-circuit breaking capacity — where this breaker holds and where it doesn't

The SCCR (short-circuit current rating) varies sharply with line voltage: 100 kA at 240 V AC, 50 kA at 400 V AC, 10 kA at 500 V AC, and 4 kA at 690 V AC. At 400 V, the 50 kA rating covers most industrial service-entrance conditions.

Terminal capacity and wiring constraints

Main circuit terminals accept screw-type connections: solid or stranded conductors 2× (1 … 2.5 mm²) and 2× (2.5 … 6 mm²), or AWG 2× (14 … 10). That's two conductors per terminal, which is useful for daisy-chaining power through the breaker. Finely stranded with core-end processing (ferrules) uses the same ranges. No auxiliary contacts are included as standard — the listing shows 0 for auxiliary contacts, but the device has an auxiliary switch slot (yes) if you need to add one later.

Environmental limits and mechanical endurance

Shock resistance is 25g for 11 ms. The main contacts are rated for 100,000 typical mechanical operations.

Frequently asked questions

Where can I buy 3RV1021-4CA10-ZW95 and what is the lead time?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm lead-time and price commitment.

What is the closest functional alternative to 3RV1021-4CA10-ZW95?

The 3RV1011-1HA10 is a smaller-frame SIRIUS motor protection breaker (lower current rating, different trip class). It will not drop into the same panel without rewiring — the terminal ranges and mounting footprint differ. For a direct replacement, stick with the 3RV1021-4CA10-ZW95.

What compliance documentation does Siemens provide for this part?

The evidence does not list specific compliance documents (RoHS, REACH, UL, IEC) for this order code. Standard Siemens SIRIUS breakers carry UL/CSA/CE markings per the series; confirm the exact certification package with the RFQ.

What is the depth of 3RV1021-4CA10-ZW95?

The depth is 96 mm. Width is 45 mm, height is 97 mm. Clearance requirements: 0 mm backwards and 0 mm at the sides.

What conductor sizes does the main circuit accept?

Solid and stranded conductors: 2x (1 … 2.5 mm²) and 2x (2.5 … 6 mm²), or AWG 2x (14 … 10). Finely stranded with ferrules uses the same ranges.

MPN