Skip to main content
Siemens 3RV1021-4CA10-ZW97 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1021-4CA10-ZW97 SIRIUS Motor Protection Circuit B

MPN3RV1021-4CA10-ZW97

Siemens SIRIUS, motor protection circuit breaker, 3RV1021-4CA10-ZW97, 22 A continuous, CLASS 10 trip, 3-pole, screw terminals, snap-on 35 mm DIN rail.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV1021-4CA10-ZW97 — Identification
ParameterValue
SeriesSIRIUS
Product designationcircuit breaker
3RV1021-4CA10-ZW97 — Electrical
ParameterValue
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated impulse withstand voltage (Uimp)6 000 V
Number of poles3
Power loss (AC, hot)10.5 W
Power loss, per pole (AC, hot)3.5 W
3RV1021-4CA10-ZW97 — Protection & Tripping
ParameterValue
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)50 kA
Breaking capacity at 500 V (AC)10 kA
Breaking capacity at 690 V (AC)4 kA
Phase-failure detectionYes
Ground-fault detectionNo
3RV1021-4CA10-ZW97 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
3RV1021-4CA10-ZW97 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementfront side
Conductor cross-section, finely stranded with ferrule2x (1 ... 2.5 mm²), 2x (2.5 ... 6 mm²)
3RV1021-4CA10-ZW97 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth96 mm
Mounting positionany
3RV1021-4CA10-ZW97 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Max. installation altitude2 000 m
3RV1021-4CA10-ZW97 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

The Siemens SIRIUS 3RV1021-4CA10-ZW97 is a 3-pole motor protection circuit breaker rated for 22 A continuous current and 11 kW at 400 V AC-3 duty. Breaking capacity is 50 kA at 400 V AC, dropping to 10 kA at 500 V and 4 kA at 690 V.

Integration Notes

Width is 45 mm. Depth is 96 mm, height is 97 mm. Screw terminals on the main circuit accept solid or stranded wire: 2x (1 … 2.5 mm²) and 2x (2.5 … 6 mm²) per pole. That covers most motor feeder cables up to 6 mm² (roughly 10 AWG). No auxiliary contacts are included — the unit has zero built-in aux contacts, so if you need a status signal, you'll add the separate auxiliary switch block (the listing confirms auxiliary switch is available as an add-on). Ground fault detection is not included, so for sensitive ground-fault protection you'd need an external module or a different breaker. Shock resistance is 25g / 11 ms, which is adequate for most industrial environments but not for extreme vibration like near a large reciprocating compressor without additional damping.

MPN