Skip to main content
Siemens 3RV1021-4CA15-ZW97 — Motor Protection Circuit Breakers (MPCB)

Siemens SIRIUS 3RV1021-4CA15-ZW97 Motor Protection Circuit B

MPN3RV1021-4CA15-ZW97

Siemens SIRIUS motor protection circuit breaker, 3RV1021-4CA15-ZW97, 22 A rated continuous current, Class 10 trip, 11 kW at 400 V, 50 kA breaking capacity at 400 V AC, screw terminals, IP20 front.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV1021-4CA15-ZW97 — Identification
ParameterValue
SeriesSIRIUS
Product designationcircuit breaker
3RV1021-4CA15-ZW97 — Electrical
ParameterValue
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated impulse withstand voltage (Uimp)6 000 V
Number of poles3
Power loss (AC, hot)10.5 W
Power loss, per pole (AC, hot)3.5 W
3RV1021-4CA15-ZW97 — Protection & Tripping
ParameterValue
Overload release setting range17 ... 22 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)50 kA
Breaking capacity at 500 V (AC)10 kA
Breaking capacity at 690 V (AC)4 kA
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV1021-4CA15-ZW97 — Endurance & Switching
ParameterValue
Auxiliary CO (changeover) contacts0
3RV1021-4CA15-ZW97 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementfront side
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor range, AWG (main contacts)2x (14 ... 10)
3RV1021-4CA15-ZW97 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth96 mm
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
Mounting positionany
3RV1021-4CA15-ZW97 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Max. installation altitude2 000 m
3RV1021-4CA15-ZW97 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

Motor protection circuit breaker, 22 A, Class 10 — SIRIUS 3RV1021-4CA15-ZW97

The Siemens SIRIUS 3RV1021-4CA15-ZW97 is a motor protection circuit breaker rated for 22 A continuous current, with a Class 10 trip characteristic and a rated motor power of 11 kW at 400 V AC. It is designed for screw-type terminal connections on both the main and auxiliary/control circuits.

Breaking capacity and fault clearing

Rated breaking capacity reaches 100 kA at 240 V AC, 50 kA at 400 V AC, 10 kA at 500 V AC, and 4 kA at 690 V AC. Ground fault detection is not integrated, meaning a separate residual-current device is needed if ground-fault protection is required.

Any mounting position is permitted, which simplifies panel layout. Zero clearance required at the sides and rear (0 mm), so units can be ganged without spacing gaps — useful when packing multiple breakers into a tight enclosure. Power dissipation in hot operating state is 10.5 W. In a sealed, non-ventilated enclosure, account for this heat contribution when sizing the thermal management.

Shock resistance rated at 25 g for 11 ms.

Main circuit screw terminals accept solid conductors: 2× (0.5 to 1.5 mm²) and 2× (0.75 to 2.5 mm²). Stranded conductors: 2× (1 to 2.5 mm²) and 2× (2.5 to 6 mm²). AWG equivalents for main contacts: 2× (14 to 10). The auxiliary switch uses transverse screw terminals.

This is a current-production Siemens SIRIUS device.

Frequently asked questions

Where can I buy 3RV1021-4CA15-ZW97 and how do I get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Submit an RFQ for current availability and pricing.

What is the breaking capacity of 3RV1021-4CA15-ZW97 at 400 V?

The rated breaking capacity at 400 V AC is 50 kA. At 240 V AC it is 100 kA, at 500 V AC it is 10 kA, and at 690 V AC it is 4 kA.

What wire sizes does 3RV1021-4CA15-ZW97 accept?

Main circuit screw terminals accept solid 2× (0.5 to 1.5 mm²) and 2× (0.75 to 2.5 mm²), stranded 2× (1 to 2.5 mm²) and 2× (2.5 to 6 mm²), and AWG 2× (14 to 10).

Does 3RV1021-4CA15-ZW97 have phase failure detection?

Yes, phase failure detection is built in. Ground fault detection is not integrated.

MPN
3RV1021-4CA15-ZW97