Siemens 3RV1021-4DA10-ZW96 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1021-4DA10-ZW96 SIRIUS Motor Protection Circuit B

MPN3RV1021-4DA10-ZW96

Siemens SIRIUS 3RV1021-4DA10-ZW96, motor protection circuit breaker, 25 A rated continuous current, CLASS 10 trip class, 3-pole, screw-type terminals, IP20 front protection, 45 x 97 x 96 mm (WxHxD).

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV1021-4DA10-ZW96 — Identification
ParameterValue
SeriesSIRIUS
Product designationcircuit breaker
3RV1021-4DA10-ZW96 — Electrical
ParameterValue
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated impulse withstand voltage (Uimp)6 000 V
Number of poles3
Power loss (AC, hot)10.5 W
Power loss, per pole (AC, hot)3.5 W
3RV1021-4DA10-ZW96 — Protection & Tripping
ParameterValue
Overload release setting range20 ... 25 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)50 kA
Breaking capacity at 500 V (AC)10 kA
Breaking capacity at 690 V (AC)4 kA
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV1021-4DA10-ZW96 — Endurance & Switching
ParameterValue
Auxiliary CO (changeover) contacts0
3RV1021-4DA10-ZW96 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementfront side
Conductor cross-section, finely stranded with ferrule2x (1 ... 2.5 mm²), 2x (2.5 ... 6 mm²)
Conductor range, AWG (main contacts)2x (14 ... 10)
3RV1021-4DA10-ZW96 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth96 mm
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
Mounting positionany
3RV1021-4DA10-ZW96 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Max. installation altitude2 000 m
3RV1021-4DA10-ZW96 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

Motor protection circuit breaker for 25 A motor circuits

The CLASS 10 curve is the most common choice for standard squirrel-cage motors; it coordinates well with contactors in a motor starter assembly.

Breaking capacity and fault clearing

The interrupting ratings are voltage-dependent: 100 kA at 240 V AC, 50 kA at 400 V AC, 10 kA at 500 V AC, and 4 kA at 690 V AC. Ground fault detection is not included (no); that requires an external module or a separate ground-fault relay.

Each pole accepts 2 conductors: solid or stranded 1 … 2.5 mm², plus a second pair of 2.5 … 6 mm². For AWG, that's 2x (14 … 10) for the main contacts. The dual-terminal design allows daisy-chaining power through the breaker without extra terminal blocks — common in motor starter wiring where the line side feeds the contactor coil.

Shock resistance is rated at 25 g for 11 ms, typical for industrial vibration environments.

Frequently asked questions

Will 3RV1021-4DA10-ZW96 drop into a panel specified around 3RV1011-1HA10 without rewiring?

Not without checking the terminal layout and dimensions. The 3RV1021-4DA10-ZW96 has a 45 mm width and 96 mm depth, while the 3RV1011-1HA10 is a different frame size. The terminal capacity differs — this unit accepts up to 6 mm² per pole, which may be larger or smaller than the 3RV1011 variant. Verify the mounting footprint and wire range against your panel layout before substituting.