Siemens 3RV1021-4DA10-ZX95 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1021-4DA10-ZX95 SIRIUS Motor Protection CB, 25A,

MPN3RV1021-4DA10-ZX95

Siemens SIRIUS 3RV1021-4DA10-ZX95 motor protection circuit breaker, 25 A continuous, Class 10 trip, 11 kW at 400 V AC-3, 50 kA SCCR at 400 V, screw terminals, snap-on DIN rail mount, IP20 front.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3RV1021-4DA10-ZX95 — Identification
ParameterValue
SeriesSIRIUS
Product designationcircuit breaker

Electrical

3RV1021-4DA10-ZX95 — Electrical
ParameterValue
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated impulse withstand voltage (Uimp)6 000 V
Number of poles3
Power loss (AC, hot)10.5 W
Power loss, per pole (AC, hot)3.5 W

Protection & Tripping

3RV1021-4DA10-ZX95 — Protection & Tripping
ParameterValue
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)50 kA
Breaking capacity at 500 V (AC)10 kA
Breaking capacity at 690 V (AC)4 kA
Phase-failure detectionYes
Ground-fault detectionNo

Endurance & Switching

3RV1021-4DA10-ZX95 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h

Connections

3RV1021-4DA10-ZX95 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementfront side
Conductor cross-section, finely stranded with ferrule2x (1 ... 2.5 mm²), 2x (2.5 ... 6 mm²)

Mechanical

3RV1021-4DA10-ZX95 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth96 mm
Mounting positionany

Environmental

3RV1021-4DA10-ZX95 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C

Specifications

3RV1021-4DA10-ZX95 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

Motor Protection Circuit Breaker — 25 A, Class 10, 50 kA SCCR

The Siemens 3RV1021-4DA10-ZX95 is a SIRIUS motor protection circuit breaker (MPCB) rated for 25 A continuous current, with a Class 10 trip characteristic for standard motor starting duty. At 400 V AC-3 it handles 11 kW loads, and the interrupting rating sits at 50 kA at 400 V AC — enough to clear a fault without upstream coordination in most distribution panels. Phase failure detection is built in; no ground fault detection on this variant. Mounts via screw and snap-on onto 35 mm DIN rail per EN 50022. The front face carries IP20 protection — adequate for enclosed panel use, not for washdown zones. Screw-type terminals on the main circuit accept 2x (1…2.5 mm²) solid or 2x (2.5…6 mm²) stranded, with AWG equivalents at 2x (14…10).

Installation & Integration

The breaker occupies 45 mm width on the DIN rail, with 96 mm depth and 97 mm height. Zero clearance required at the sides or rear — 0 mm backwards and 0 mm at the side — so it fits tight panel layouts. Operating temperature range is -20 to +60 °C; storage and transport from -50 to +80 °C. Shock rated at 25g for 11 ms. Mounting position is unrestricted.

Coordination & Ratings

The interrupting capacity steps down with voltage: 100 kA at 240 V AC, 50 kA at 400 V, 10 kA at 500 V, and 4 kA at 690 V. Rated impulse withstand voltage is 6 kV. Power dissipation at rated current in hot operating state is 10.5 W total, 3.5 W per pole. Mechanical endurance on the main contacts is 100,000 operations typical. An auxiliary switch is included as standard (0 auxiliary contacts for the main circuit — the auxiliary switch is a separate integrated unit). The maximum switching frequency at AC-3 duty is 15 operations per hour.

Frequently asked questions

What is the depth of 3RV1021-4DA10-ZX95?

The depth is 96 mm, with 0 mm required clearance at the rear.

What conductor sizes does the terminal accept?

Screw terminals accept 2x (1…2.5 mm²) solid or stranded, or 2x (2.5…6 mm²) finely stranded with ferrules. AWG equivalent is 2x (14…10).

MPN
3RV1021-4DA10-ZX95