Siemens 3RV1031-4AA10-ZX95 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1031-4AA10-ZX95 SIRIUS Motor Protection Circuit B

MPN3RV1031-4AA10-ZX95

Siemens SIRIUS, motor protection circuit breaker, 3RV1031-4AA10-ZX95, 16 A continuous, 7.5 kW at 400 V, Trip Class 10, 50 kA breaking capacity, screw terminals, DIN rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3RV1031-4AA10-ZX95 — Identification
ParameterValue
SeriesSIRIUS
Product designationcircuit breaker
3RV1031-4AA10-ZX95 — Electrical
ParameterValue
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated impulse withstand voltage (Uimp)6 000 V
Number of poles3
Power loss (AC, hot)14.5 W
Power loss, per pole (AC, hot)4.8 W
3RV1031-4AA10-ZX95 — Protection & Tripping
ParameterValue
Overload release setting range11 ... 16 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)50 kA
Breaking capacity at 500 V (AC)12 kA
Breaking capacity at 690 V (AC)5 kA
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV1031-4AA10-ZX95 — Endurance & Switching
ParameterValue
Auxiliary CO (changeover) contacts0
3RV1031-4AA10-ZX95 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals with box terminals
Main-circuit connector arrangementfront side
Conductor cross-section, finely stranded with ferrule2x (0.75 ... 16 mm²), 0.75 ... 25 mm²
Conductor range, AWG (main contacts)2x (18 ... 2), 1x (18 ... 2)
3RV1031-4AA10-ZX95 — Mechanical
ParameterValue
Height140 mm
Width55 mm
Depth149 mm
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
Mounting positionany
3RV1031-4AA10-ZX95 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Max. installation altitude2 000 m
3RV1031-4AA10-ZX95 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

Motor protection circuit breaker for the SIRIUS line

It carries a continuous current rating of 16 A and delivers 7.5 kW at 400 V AC, with a Trip Class 10 thermal-magnetic trip curve — meaning it protects standard induction motors during start-up without nuisance tripping on inrush.

Main circuit terminals accept solid conductors 2x (0.75... 16 mm²) and stranded 2x (0.75... 25 mm²) or 1x (0.75 … 35 mm²). AWG equivalents are 2x (18... 2) for the main contacts. The screw-type box terminals are standard for panel wiring — torque to the manufacturer's spec for full short-circuit rating. Auxiliary and control circuits also use screw terminals. The product extension auxiliary switch is available (not included), so you can wire a remote status signal or a PLC input without a separate interface relay. Depth is 149 mm, width 55 mm, height 140 mm — fits the standard SIRIUS 3RV1 footprint. Backwards and side clearance is 0 mm, so adjacent breakers can be mounted flush without derating.

RoHS compliance date is 07/01/2006, covering the EU directive. No ground fault detection is built in — that function is handled separately by a residual current device upstream if required.

Frequently asked questions

Where can I buy 3RV1031-4AA10-ZX95?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is the breaking capacity of 3RV1031-4AA10-ZX95 at 400 V?

50 kA at 400 V AC, which covers most industrial distribution panels without requiring upstream current-limiting fuses.

Does 3RV1031-4AA10-ZX95 include phase failure detection?

Yes, phase failure detection is built in — a lost phase trips the breaker before the motor single-phases to failure.

MPN
3RV1031-4AA10-ZX95